Product Overview
The PST-360 is a sensor featuring a digital Serial Peripheral Interface (SPI) protocol, designed to operate as a slave node. It provides angle measurement data continuously calculated by the slave, which is then held for the master to read. The device supports a 360 ERA (Electronic Rotary Angle) measurement with a resolution indicated by the rotor size. It is suitable for applications requiring precise angular positioning and digital communication.
Product Attributes
- Brand: Piher Sensors & Controls SA
- Company Affiliation: AmphenolTM company
- Origin: Spain
- Protocol: SPI Protocol (Simple - SPI Protocol)
- Output Function: Curve 0000
Technical Specifications
| Specification | Value | Details |
|---|---|---|
| Model | PST360G2-1S-C0000-ERA360-05K | |
| Rotor | 14mm | |
| Supply Voltage (Vdd) | 5V 10% | |
| Temperature Range | -40 C to +125 C | |
| Signal Output Type | Digital | SPI Protocol (360 ERA) |
| SPI Pins | /SS, SCLK, MOSI-MISO | All 5V tolerant digital inputs/outputs. MOSI-MISO is open drain. |
| Slave Start-Up Time | < 16 s | Time within which /SS and SCLK are ignored. First frame can be sent after 16 ms. |
| Slave Reset Time | 1 second (after internal soft failures) | |
| Data Frame Structure | 10 bytes | 2 start bytes (AAh, FFh), 2 data bytes (DATA16), 2 inverted data bytes (/DATA16), 4 all-Hi bytes. |
| Timing (Slow Mode, 7MHz Oscillator) | t1: 6.9 s (Min) | Minimum clock period for any bits within a byte. |
| t2: 37.5 s (Min) | Minimum time between any other byte. | |
| t4: 6.9 s (Min) | Minimum time between /SS=Lo and the first clock edge. | |
| t5: 1500 s (Min) | Minimum time between reset-inactive and any master signal change. | |
| t5: 0 ms (Min) | Maximum /SS=Hi time where NO frame re-synchronizations will be started. | |
| t6: 6.9 s (Min) | ||
| t7: 45 s (Min) | Minimum time between StartByte and Byte0. | |
| t9: < 1 s | Time between last clock and /SS=high=chip de-selection. | |
| Error Handling | ROM CRC error, EEPROM CRC error, RAM check error, intelligent watchdog error | Slave serial protocol is not initialized. MOSI/MISO remains Hi-impedant. |
2411220423_Amphenol-PST360G2-2AA-C0123-ERA040-05K_C3825114.pdf
Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible