Product Overview
The Telaire 8000 Ventostat series offers reliable wall-mount CO2, humidity, and temperature transmitters designed for controlled ventilation in commercial HVAC applications. These transmitters help maintain indoor air quality, prevent energy losses from over-ventilation, and ensure a healthy, productive environment. Featuring patented sensing technologies like Absorption Infrared Gas sensing and ABC Logic self-calibration, they provide high accuracy and minimize maintenance needs. The two-piece design allows for easy installation and replacement without rewiring. Available in various configurations, including models with BACnet output, dual analog outputs, and optional displays, the Ventostat 8000 series is suitable for areas with fluctuating occupancy, such as conference rooms, classrooms, and meeting halls.
Product Attributes
- Brand: Telaire, Amphenol Advanced Sensors
- Series: Ventostat 8000
- Sensing Technology: Patented Absorption Infrared Gas sensing engine, ABC Logic self-calibration system
- Calibration Guarantee: Lifetime for T8100/T8300 (ABC Logic enabled), 2 years for T8200
- Enclosure: Modern, customizable branding available, smaller enclosure versions available (81.4 mm x 86.4 mm)
- Design: Two-piece design for easy replacement
- Certifications: CE, RoHS compliant
- Filter: Gas permeable, water resistant CO2 diffusion filter
- Optional Accessories: Splash Resistant Enclosure (T1505), Outside Air Enclosure (T1552), Aspiration Box for Duct Mounting (T1508)
- Software: Ventostat UIP Software for configuration and calibration
Technical Specifications
| Specification | Details |
|---|---|
| CO2 Measurement Range | T8100/T8200/T8300: 0 to 2000 ppm T8100/T8200/T8300 - 5P: 0 to 5000 ppm T8200 (10P): 0 to 10,000 ppm T8200 (20P): 0 to 20,000 ppm |
| CO2 Accuracy | 30ppm or 3% of the reading shown, whichever is higher* |
| Power Supply Requirements | 18-30 VAC RMS, 50/60 Hz, or 10.8 to 42 VDC, polarity protected |
| Power Consumption | Typical 0.7 W at 24V AC RMS |
| Temperature Dependence | 0.2% FS per C (0.11% per F) |
| Stability | T8100/T8300 (Single Channel): <2% of FS over life (15 years) T8200 (Dual Channel): <5% of FS or <10% reading annual over life (10 years) |
| Pressure Dependence | 0.135% of reading per mm Hg |
| Warranty | 24 months on mechanical defects |
| Signal Update | Every 5 seconds |
| CO2 Warm-up Time | < 2 minutes (operational), 10 minutes (maximum accuracy) |
| Operating Conditions | 32F to 122F (0C to 50C), 0 to 95% RH (non-condensing) |
| Storage Conditions | -40F to 158F (-40C to 70C) |
| Flammability Classification | UL94 5VA |
| Thermistor Type | NTC 10 K W (Passive, not BACnet version) |
| Thermistor Accuracy | 1C (15 to 35C) |
| RH Sensing Element | Capacitive polymer sensor |
| RH Range | 0% to 99% RH (non-condensing) |
| RH Accuracy (25C) | 2.5% RH (20 to 80% RH), 3.5% RH (<20% and >80% RH) |
| Active Temperature Accuracy | 0.8C @ 22C |
| Active Temperature Range | 32F to 122F (0 to 50C) |
| Analog Output Version | 0 to 10 V (100 W impedance) and 4 to 20mA (RL max 500 W) simultaneous |
| BACnet Version | MS/TP, RS485, Baud rates 38400 or 9600 |
| Models | T8100 (Single Channel, ABC Logic), T8200 (Dual Channel), T8300 (Single Channel with Pitot Tube Kit) |
| Ordering Information Examples | T8100-D, T8100-D-BAC, T8200-HD, T8300-BAC, T8100-DB |
| Field Replaceable Sensor | RH sensor tip module (maintains 2.5% RH accuracy) |
| Pitot Tube Kit | For duct measurement of CO2 (T8300) |
| UIP Software Features | Altitude adjustment, analog output adjustment, calibration, ABC Logic control, temperature unit change, graphing/logging (H versions) |