Online Service

Online Service

Contact Person
+86 136 6733 2386
quality Durable loop powered vibration transmitter Amphenol PC421VP-30-IS for critical equipment maintenance factory
<
quality Durable loop powered vibration transmitter Amphenol PC421VP-30-IS for critical equipment maintenance factory
>
Specifications
Mfr. Part #:
PC421VP-30-IS
Key Attributes
Model Number: PC421VP-30-IS
Product Description

Product Overview

Wilcoxon's 4-20 mA LPS Series transducers are self-contained vibration transmitters designed to integrate directly with Programmable Logic Controllers (PLCs) or Distributed Control Systems (DCS). These loop-powered sensors enable plant personnel to continuously monitor overall vibration levels, trend machine health, correlate vibration data with operating conditions, and schedule maintenance tasks. They are crucial for Condition Based Maintenance (CBM) programs, providing essential vibration information even without a dedicated vibration analysis technician. Wilcoxon LPS transducers offer a cost-effective and reliable solution for monitoring critical machinery, preventing failures, and reducing downtime.

Product Attributes

  • Brand: Wilcoxon Sensing Technologies
  • Product Series: LPS Series
  • Certifications: CSA (U.S. and Canada), LCIE ATEX
  • Hazardous Area Ratings: Intrinsically Safe (IS), Explosion Proof (EX)
  • Measurement Basis: Velocity or Acceleration
  • Output Signal: 4-20 mA loop powered

Technical Specifications

Feature/Model Description Details
Measurement Types Overall Vibration Velocity or Acceleration
Output Signal Options 4-20 mA Calibrated in Peak, RMS, or True Peak
Frequency Banded Transducers Low Frequency (PC420VP-10-B3041) 3 Hz to 40 Hz (180 RPM to 2400 RPM) for balance/alignment issues
High Frequency (PC420AR-10-3223) 300 Hz to 2,000 Hz (18,000 RPM to 120,000 RPM) for pump cavitation
Dual Output Transducers 4-20 mA vibration signal + Dynamic signal Dynamic signal can be 100 mV/g (acceleration) or 100 mV/ips (velocity)
Hazardous Area Installations Intrinsically Safe Models (-IS) CSA Class 1, Div 1, GRPS A, B, C, D T3C; ATEX EEx ia IIC T3
Explosion Proof Models (-EX) CSA Class 1, Div 1, 2 GRPS A, B, C, D; Class 2, Div 1, 2 GRPS E, F, G; Class 3, Div 1, 2 T3; ATEX EEx d IIC T3, EEx nA IIC T3
Model Numbering Convention PC420/PCC421/PCC423/PC425/PC427 Base model (e.g., PC420 for top exit, PCC421 for side exit)
Measurement Type AP (Accel Peak), AR (Accel RMS), ATP (Accel True Peak), VP (Vel Peak), VR (Vel RMS), VTP (Vel True Peak)
Full Scale Range -05 (e.g., 0.5 ips), -10 (e.g., 1.0 ips), -20 (e.g., 2.0 ips), -30, -50
Optional Configurations DA (Dynamic Accel), DV (Dynamic Vel), IS (Intrinsically Safe), EX (Explosion Proof)
Cabling/Connections R6 (integral cable), M12-4 (connector), J9T2A, J10, J9T4, J9T4A, J95
Example Models PC420VP-10 Velocity, Peak calibrated, 1.0 ips full scale
PC420VP-10-DA Velocity, Peak calibrated, 1.0 ips full scale, with Dynamic Acceleration output (100 mV/g)
PC420VP-10-IS Velocity, Peak calibrated, 1.0 ips full scale, Intrinsically Safe rated
PC420VP-10-B3041 Velocity, Peak calibrated, 1.0 ips full scale, Band-limited 3-40 Hz
PC420AR-10-B3223 Acceleration, RMS calibrated, 10 g full scale, Band-limited 300-2,000 Hz

2506301128_Amphenol-PC421VP-30-IS_C3319007.pdf

Request A Quote

Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible

You Can Upload Up To 5 Files And Each File Sized 10M Max