Wilcoxon Sensing Technologies 4-20 mA LPSTM Series Transducer Selection Guide
Product Overview
Wilcoxon's Loop Powered Sensors (LPS) are self-contained 4-20 mA vibration transmitters designed to integrate directly with Programmable Logic Controllers (PLCs) or Distributed Control Systems (DCS). These sensors enable plant personnel to continuously monitor overall vibration levels, trend machine health, and correlate vibration data with operating conditions. This capability facilitates effective Condition Based Maintenance (CBM) programs, allowing for proactive scheduling of maintenance tasks and preventing machine failures, even in the absence of dedicated vibration analysis technicians. LPS transducers offer a convenient, reliable, and cost-effective solution for machinery condition monitoring, providing a direct 4-20 mA signal proportional to average vibration, thereby aiding in operational efficiency and cost reduction.
Product Attributes
- Brand: Wilcoxon Sensing Technologies
- Series: LPSTM (Loop Powered Sensors)
- Origin: USA
- Certifications: CSA (for U.S. and Canada), LCIE ATEX
- Hazardous Area Approvals: Intrinsically Safe (IS), Explosion Proof (EX)
Technical Specifications
| Feature / Model Component | Description / Specification |
|---|---|
| Measurement Principle | Velocity or Acceleration |
| Output Signal | 4-20 mA loop powered |
| Output Calibration Options | Peak, True Peak, RMS (for broadband); Peak, RMS (for frequency banded) |
| Dual Output Options | Temperature and 4-20 mA vibration; Dynamic (Acceleration or Velocity) and 4-20 mA vibration |
| Frequency Banded Transducers |
|
| Hazardous Area Installations |
|
| Model Number Structure | PC42[Exit]-[Range]-[Options] or PCC42[Exit]-[Range]-[Options] |
| Exit Types | Top exit (PC420), Side exit (PC421, PC423), Side exit with temperature sensor (PC425, PC427) |
| Ranges | -05, -10, -20, -30, -50 (specific units for velocity or acceleration) |
| Optional Configurations | DA (Dynamic Acceleration), DV (Dynamic Velocity), IS (Intrinsically Safe), EX (Explosion Proof) |
| Cabling / Connections | Integral cable (standard 16'), R6, M12-4, J9T2A, J10, J9T4, J9T4A, J95 (specific to model) |
| Example Model: PC420VP-10 | Velocity, Peak calibrated output, 1.0 ips full-scale range. |
| Example Model: PC420VP-10-DA | Velocity, Peak calibrated output, 1.0 ips full-scale range, with additional Dynamic Acceleration output (100 mV/g). |
| Example Model: PC420VP-10-IS | Velocity, Peak calibrated output, 1.0 ips full-scale range, Intrinsically Safe rated. |
| Example Model: PC420VP-10-B3041 | Velocity, Peak calibrated, 1.0 ips full-scale, band-limited 3-40 Hz. |
| Example Model: PC420AR-10-B3223 | Acceleration, RMS calibrated, 10 g full-scale, band-limited 300-2,000 Hz. |
2412111045_Amphenol-PC421VR-10-IS_C3319125.pdf
Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible