Online Service

Online Service

Contact Person
+86 136 6733 2386
quality vibration monitoring device Amphenol PCH420V-M12-HZ featuring HART 7 protocol and hermetic sealing factory
<
quality vibration monitoring device Amphenol PCH420V-M12-HZ featuring HART 7 protocol and hermetic sealing factory
quality vibration monitoring device Amphenol PCH420V-M12-HZ featuring HART 7 protocol and hermetic sealing factory
>
Specifications
Mfr. Part #:
PCH420V-M12-HZ
Key Attributes
Model Number: PCH420V-M12-HZ
Product Description

Product Overview

The Wilcoxon PCH420V series is a HART-enabled vibration transmitter designed for continuous asset monitoring. It offers a 4-20 mA output with HART 7.0 digital communication, enabling remote configuration, diagnostics, and multi-drop loop installations. This series provides user-configurable bands for vibration analysis, allowing for tailored monitoring of machinery health. With hazardous area certified models available, the PCH420V series is suitable for demanding industrial environments, simplifying connectivity into plant networks and improving operational efficiency.

Product Attributes

  • Brand: Wilcoxon Sensing Technologies (An Amphenol Company)
  • Origin: USA
  • Certifications: Class I, Div 2 Groups A, B, C, D; Class I, Zone 2 AEx/Ex nA nC IIC T4; II 3 G Ex nA nC IIC T4 Gc (for -HZ models)
  • Manufacturing Standard: ISO 9001
  • Case Material: 316L stainless steel
  • Sealing: Hermetic
  • Sensing Element: PZT, shear

Technical Specifications

Model Description Connector Type Hazardous Area Certified Dimensions (Approx.)
PCH420V-R6 4-20 mA + HART velocity sensor 2 pin MIL-C-5015 No 2.52 [ 64.0 mm ] (Body Length)
PCH420V-R6(-HZ) 4-20 mA + HART velocity sensor 2 pin MIL-C-5015 Yes 2.52 [ 64.0 mm ] (Body Length)
PCH420V-M12 4-20 mA + HART velocity sensor 4 pin M12 No 2.75 [ 69.9 mm ] (Body Length)
PCH420V-M12(-HZ) 4-20 mA + HART velocity sensor 4 pin M12 Yes 2.75 [ 69.9 mm ] (Body Length)
Parameter Specification
Output 4-20 mA + HART 7.0
HART Device Variables PV - Vibration band 1, SV - Vibration band 2, TV - Vibration band 3
Programmable PV Band 0.5 - 5.0 in/sec, peak (12.7 - 127 mm/sec, peak)
HART Analysis Bands Independently programmable: low-pass, high-pass, band-pass (max 2, simultaneous)
Signal Detection Options RMS, peak, true peak
Minimum Analysis Bandwidth 10 Hz
Frequency Response 10% (10 Hz - 1 kHz); 3 dB (3.0 Hz - 1.95 kHz)
Measurement Accuracy 5% at 25C, 100 Hz, 1 ips full scale
Power Requirements (2-wire loop) Voltage: 12 - 30 VDC; Current Draw: 3.8 - 22 mA
Loop Resistance (at 24 VDC) Max 600
Turn On Time (4-20 mA loop) 30 seconds
Grounding Case isolated, internally shielded
Temperature Range 40 to +105 C (40 to +221F)
Vibration Limit 500 g peak
Shock Limit 5,000 g peak
Mounting 1/4-28 tapped hole
Mating Connector (-R6 models) 2 pin, MIL-C-5015
Mating Connector (-M12 models) 4 pin, M12
Recommended Cabling J9T2A
Recommended Connector (-R6) R75S
Accessories Supplied SF6 mounting stud; calibration data; DD (Device Description) file
Connections - PCH420V-R6 Function Connector Pin
Loop Positive A
Loop Negative B
Ground Shell Shell
Connections - PCH420V-M12 Function Connector Pin
Loop Positive 1
Loop Negative 2
N/C 3
N/C 4
Ground Shell Shell

2504101957_Amphenol-PCH420V-M12-HZ_C17636573.pdf