Specifications
Mfr. Part #:
PCH420V-M12
Key Attributes
Model Number: PCH420V-M12
Product Description

Product Overview

The Wilcoxon Sensing Technologies PCH420V series is a HART-enabled vibration transmitter designed for continuous asset monitoring. It features a 4-20 mA output with the added capability of digital communications via the HART protocol (7.0). This allows for user configuration of sensors, multi-drop cable installations, and direct communication with HART-enabled DCS or PLCs. The PCH420V series offers three user-configurable bands for vibration analysis, enabling flexible full-scale range and filter settings. Benefits include reduced cabling requirements and simplified integration into existing plant infrastructure, leading to improved connectivity, efficiency, and machinery health decision-making. Hazardous area certified models are available.

Product Attributes

  • Brand: Wilcoxon Sensing Technologies
  • Company: An Amphenol Company
  • Origin: USA
  • Certifications: Class I, Div 2 Groups A, B, C, D; Class I, Zone 2 AEx/Ex nA nC IIC T4; II 3 G Ex nA nC IIC T4 Gc (for -HZ models)
  • Manufacturing Standard: Approved ISO 9001 facility
  • Case Material: 316L stainless steel
  • Sensing Element: PZT, shear
  • Sealing: Hermetic
  • Connector Options: 2 pin MIL-C-5015 (-R6 models) or 4 pin M12 (-M12 models)

Technical Specifications

Specification Details
Model Series PCH420V
Output Signal 4-20 mA + HART 7.0
Device Variables PV - Vibration band 1, SV - Vibration band 2, TV - Vibration band 3
Programmable PV Band 0.5 - 5.0 in/sec, peak (12.7 - 127 mm/sec, peak)
HART Analysis Bands Independently programmable: low-pass, high-pass, band-pass (max 2, simultaneous)
Signal Detection Options RMS, peak, true peak
Minimum Analysis Bandwidth 10 Hz
Frequency Response 10% (10 Hz - 1 kHz), 3 dB (3.0 Hz - 1.95 kHz)
Measurement Accuracy 5% at 25C, 100 Hz, 1 ips full scale
Power Requirements 2-wire loop power: 12 - 30 VDC
Current Draw 3.8 - 22 mA
Loop Resistance (max) 600 at 24 VDC (Note 1)
Turn on Time (4-20 mA loop) 30 seconds
Grounding Case isolated, internally shielded
Temperature Range 40 to +105 C (40 to +221F)
Vibration Limit 500 g peak
Shock Limit 5,000 g peak
Mounting 1/4-28 tapped hole
Dimensions (approx.) -R6 model: 2.75" (69.9 mm) height, 0.97" (24.6 mm) diameter
-M12 model: 2.52" (64.0 mm) height, 0.97" (24.6 mm) diameter
Model PCH420V-R6(-HZ) 4-20 mA + HART velocity sensor with 2 pin MIL-C-5015 connector
Model PCH420V-M12(-HZ) 4-20 mA + HART velocity sensor with 4 pin M12 connector
Hazardous Area Certification (-HZ models) Class I, Div 2 Groups A, B, C, D; Class I, Zone 2 AEx/Ex nA nC IIC T4; II 3 G Ex nA nC IIC T4 Gc (Tamb: -40C to +105C)
Hazardous Area Installation Notes Cable suitable for Zone 2, minimum IP54 ingress protection, connection requires tool for separation, grounding via metal mounting stud if required.

Note 1: Maximum loop resistance (RL) can be calculated by: VDC power 10.3 V / 22.8 mA. HART communication requires a minimum of 250 resistance.