Online Service

Online Service

Contact Person
+86 136 6733 2386
quality Versatile CO2 Sensor Amphenol T3032-2-5K-24-P for Subway Stations Railway Carriages and Glass Houses factory
<
quality Versatile CO2 Sensor Amphenol T3032-2-5K-24-P for Subway Stations Railway Carriages and Glass Houses factory
>
Specifications
Operating Temperature:
0℃~+50℃
Mfr. Part #:
T3032-2-5K-24-P
Key Attributes
Model Number: T3032-2-5K-24-P
Product Description

Product Overview

The Amphenol Advanced Sensors Telaire T3030 Series CO2 Sensors are designed for accurate CO2 measurement in harsh or difficult environments. These sensors feature a Non-Dispersive Infrared (NDIR) measuring technology and are available with analog or digital output options. They offer easy mounting with external tabs and are rated up to IP67, with options for potting for enhanced protection. The T3030 Series is suitable for a wide range of applications including HVAC control, incubators, buses, refrigerators, subway stations, railway carriages, and agricultural settings like glass houses and animal sheds. Single wavelength models utilize ABC Logic self-calibration for reduced maintenance, while dual wavelength models offer extended accuracy and calibration guarantees.

Product Attributes

  • Brand: Amphenol Advanced Sensors Telaire
  • Sensing Method: Non-Dispersive Infrared (NDIR), single or dual wavelength
  • IP Class: Up to IP67 (dust tight and immersion to 1m)
  • Flammability Classification: To UL94 5VA (dependent upon build)
  • Calibration Guarantee: Lifetime for single wavelength, two-year for dual wavelength
  • Output Options: Analog (0-5 V, 0-10 V, 4-20mA), Digital (Modbus, UART)
  • Measuring Technology Options: Single Wavelength with ABC Logic, Dual Wavelength

Technical Specifications

Specification Details
Product Series T3030 Series
Power Supply Requirements 15 15 VDC 10%, 24 - 18-30 VAC RMS, 50/60 Hz, or 18 to 42 VDC, polarity protected
Power Consumption Typical 0.7 W at nominal voltage of 24V AC RMS
Resolution Minimum 10bit or analog equivalent
Accuracy (Single Wavelength, 0~2,000 ppm example) 400-1250 ppm 30 ppm or 3% of reading, whichever is greater*, **
1250-2000 ppm 5% of reading + 30ppm *, **
Accuracy (Dual Wavelength, 0~2,000 ppm example) 75 ppm or 10% of reading (whichever is greater)
Accuracy (Dual Wavelength, 0~200,000 ppm example) 5% of reading or 0.3 vol% CO2 (whichever is larger) at 0 - 20 vol% CO2 and 0C to +25C
At 25C to 50C additional 0.1% of reading or 0.01 vol% CO2 (whichever is larger) per degree C.
Temperature Dependence 0.2% FS / C
Response Time (tau 63%) < 200 sec
Aging (Dual Wavelength Only) +/- 5% of reading annual drift. Less than +/- 25% of reading within product life time.
Recommended Recalibration Interval Single Wavelength No calibration required
Dual Wavelength - 1 year
Working Temperature 0 to +50C (measures within tolerance)
Operation Temperature (Sensor Is Powered) -30 to +50C
Storage Temperature -40 to +70C
Minimum Lifetime 10 years or 30,000 operating hours
RH Range 0% to 99% RH (non-condensing)
Atmospheric Conditions (Tested) Marine, salt mist and particles present; O2 level 0-21 vol%; 0 to 100% RH; Ammonium max 200mg/m3; S02 max 0.5 vol%; Ethylene max 500ppm vol; Ozone
Output Configurations Analog: 0 to 5 V, 0 to 10 V, 4 to 20mA
Digital: Modbus, UART
Analog Output Error 1%
Example Models T3031-2-2K-24-P (Dual Channel, 0-2000 PPM, 0 to 10 VDC o/p, Potted)
T3031-2-5K-24-P (Dual Channel, 0-5000 PPM, 0 to 10 VDC o/p, Potted)
T3032-2-5K-24-P (Dual Channel, 0-5000 PPM, 4 to 20 mA o/p, Potted)
T3032-2-10K-24-P (Dual Channel, 0-10,000 PPM, 4 to 20 mA o/p, Potted)
T3032-2-20K-24-P (Dual Channel, 0-20,000 PPM, 4 to 20 mA o/p, Potted)
Available Calibrations 0-2K, 0-5K, 0-10K, 0-20K

2411272128_Amphenol-T3032-2-5K-24-P_C1526461.pdf

Request A Quote

Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible

You Can Upload Up To 5 Files And Each File Sized 10M Max