Specifications
Operating Temperature:
-40℃~+75℃
Mfr. Part #:
INIR2-ME5%
Key Attributes
Model Number: INIR2-ME5%
Product Description

Product Overview

The INIR2-ME5% is a user-friendly digital Gas Sensor designed for detecting methane gas leaks in industrial and residential environments. Leveraging SGX Sensortechs non-dispersive infrared technology and power-efficient CORTEX microcontrollers, it offers high flexibility, functionality, and a linear output proportional to gas concentration. Key advantages include temperature compensation, good accuracy, low voltage DC power supply, and simple implementation. It is factory calibrated for up to 5% Methane and designed for use in hazardous areas, holding ATEX and IECEx certifications.

Product Attributes

  • Brand: SGX Sensortech
  • Model: INIR2-ME5%
  • Technology: Non-dispersive infrared (NDIR)
  • Certifications: ATEX, IECEx (I M2 Ex db I Mb, II 2G Ex db IIC Gb)
  • Body Material: Stainless Steel
  • Origin: Poland (SGX Europe Sp. z o.o.)

Technical Specifications

Specification Details
Methane Measurement Range Triple Range: 0-1%vol.; 1-4%vol.; 4-5%vol. (Automatic Switchover)
High Resolution Up to 10ppm
Detectivity Level 100ppm
Analog Output Resolution 12-Bit (0.0-2.5 Volts DC Max)
Serial Communication UART (Default: 38400 baud, supports 115200, 19200, 9600)
Power Supply 3.2 VDC (Min) to 5.25 VDC (Max), 3.3 VDC (Typical)
Average Current Consumption 30mA (Min), 32mA (Typical), 35mA (Max)
Logic Output (VOL) 0.6V Maximum (at 1.6mA source current)
Logic Output (VOH) 2.0V Minimum (at 1.6mA source current)
Logic Input (VIL) 0.4V Maximum
Logic Input (VIH) 2.0V Minimum
Operating Humidity 0% to 99% RH (50% RH Typical)
Storage Humidity 0% to 90% RH (50% RH Typical)
Operating Temperature -40C to 75C
Storage Temperature -20C to 55C
Temperature Cycle Limits 0.8C/min (Typical), 1.3C/min (Max)
Operating Pressure 80kPa to 120kPa
Storage Pressure 80kPa to 120kPa
Weight 20 g (Min), 23 g (Typical), 25 g (Max)
Gas Sensor Sockets 5-Pin, Polygon Topology
Warm-Up Time 45 seconds
Response Time (T90, without dust filter) Typical: ~20 sec, Max: ~30 sec
Power Input 1.5W Maximum