Specifications
Measurement Range:
800mbar~1200mbar
Operating Temperature:
-30℃~+50℃
Mfr. Part #:
SGX-4DT
Key Attributes
Model Number: SGX-4DT
Product Description

Product Overview

The SGX-4DT Industrial Dual Toxic Sensor is designed for the detection of Carbon Monoxide (CO) and Hydrogen Sulfide (H2S). It is specifically intended for use in portable multi-gas detectors. This sensor offers a reliable and accurate measurement of CO and H2S concentrations within defined ranges, featuring a linear response and a long-term output drift of less than 10% per annum. The sensor is designed for operation under a wide range of industrial conditions and is RoHS compliant.

Product Attributes

  • Brand: SGX
  • Model: SGX-4DT
  • Type: Industrial Dual Toxic Sensor
  • Gases Detected: Carbon Monoxide (CO), Hydrogen Sulfide (H2S)
  • Application: Portable Multi-Gas Detectors
  • Certifications: RoHS compliant
  • Warranty: 2 years
  • Bias: No Bias

Technical Specifications

Specification Value
Performance Range (CO) 0 500 ppm
Performance Range (H2S) 0 200 ppm
Output Signal (CO) 80 30 nA/ppm
Output Signal (H2S) 775 275 nA/ppm
Typical Baseline Range (CO equivalent) 2 ppm
Typical Baseline Range (H2S equivalent) 0.5 ppm
Filter Capacity (CO) > 20000 ppm hours
Linearity Linear
Response Time (T90) <30 s
Maximum Overload (CO) 2000 ppm
Maximum Overload (H2S) 500 ppm
Long-Term Output Drift <10% per annum
Recommended Load Resistor (CO) 10 ohms
Recommended Load Resistor (H2S) 10 ohms
Repeatability (CO equivalent) <3%
Repeatability (H2S) <2%
Resolution (CO) 1 ppm typical
Resolution (H2S) 0.5 ppm typical
Operating Temperature Range -30C to +50C
Operating Humidity 15 90% RH (non-Condensing)
Pressure Range 800 to 1200 mbar
Recommended Storage Temperature 0C to 20C
Storage Life 6 months in original Packaging (0 to 20C)
Expected Operating Life > 24 months in air
Intrinsic Safety: Maximum at 2000 ppm 0.3 mA
Intrinsic Safety: Maximum o/c Voltage 1.3 V
Intrinsic Safety: Maximum s/c Current <1.0 A
Product Dimensions All dimensions in mm, all tolerances 0.15 mm

Note: All performance is based on conditions at 20C, 50% RH and 1 atm, using SGX recommended circuitry. Sensor performance is temperature dependent.


2411261432_Amphenol-SGX-4DT_C3659304.pdf

Request A Quote

Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible

You Can Upload Up To 5 Files And Each File Sized 10M Max