Online Service

Online Service

Contact Person
+86 136 6733 2386
quality Durable Industrial Carbon Monoxide Sensor Amphenol SGX-4CO-10K with T90 Response Under 40 Seconds factory
<
quality Durable Industrial Carbon Monoxide Sensor Amphenol SGX-4CO-10K with T90 Response Under 40 Seconds factory
>
Specifications
Measurement Range:
800mbar~1200mbar
Operating Temperature:
-30℃~+50℃
Mfr. Part #:
SGX-4CO-10K
Key Attributes
Model Number: SGX-4CO-10K
Product Description
Product Overview

The SGX-4CO-10k is an industrial Carbon Monoxide (CO) sensor designed for detecting high concentrations of CO. It offers a measurement range of 0 10,000 ppm with linearity up to 2000 ppm and a T90 response time of less than 40 seconds. This sensor is suitable for applications requiring reliable CO monitoring in demanding environments. Its expected operating life is over 24 months in air, with a long-term output drift of less than 5% per annum.

Product Attributes
  • Brand: SGX Sensortech
  • Model: SGX-4CO-10k
  • Compliance: RoHS compliant
Technical Specifications
Specification Value
Measurement Range 0 10,000 ppm
Maximum Overload 100,000 ppm
Linearity Linear up to 2000ppm
Repeatability < 2% CO equivalent
Output Signal 20 10 nA / ppm
Typical Baseline Range (pure air) 20ppm CO equivalent
T90 Response Time < 40 seconds
Filter Capacity >20,000 ppm hours
Long Term Output Drift < 5% per annum
Expected Operating Life > 24 months in air
Recommended Storage Temp 0C to 20C
Temperature Range (Operating) -30C to +50C
Pressure Range (Operating) 800 to 1200 mbar
Operating Humidity Range 15%-90% RH
Recommended Load Resistor 10 ohms
Resolution (Electronics dependent) <5 ppm typical
Max at 2000ppm 0.3 mA
Max o/c Voltage 1.3 V
Max s/c Current <1.0 A
Cross Sensitivity - Hydrogen Sulphide (50 ppm) <0.1 ppm
Cross Sensitivity - Sulphur dioxide (20 ppm) 0 ppm
Cross Sensitivity - Hydrogen (100 ppm) <35 ppm
Cross Sensitivity - Nitric Oxide (50 ppm) <10 ppm
Cross Sensitivity - Ethanol (200 ppm) <1 ppm
Cross Sensitivity - Ammonia (50 ppm) 0 ppm
Cross Sensitivity - Chlorine (15 ppm) <1 ppm
Cross Sensitivity - Ethylene (100 ppm) 96 ppm
Cross Sensitivity - Acetylene (100 ppm) 90 ppm

Important Notes: All performance specifications are based upon environmental conditions of 20C, 50% relative humidity, 101kPa. Cross Sensitivity Data is for information only and calibration with target gas is recommended. Cross sensitivities may fluctuate and may differ from batch to batch or across sensors life time. Avoid exposure to high concentrations of solvent vapours. Use PSB sockets for connection; do not glue or solder to connector pins. For details on recommended connector pins, refer to the SGX website FAQ. Electrochemical gas sensors can potentially fail to meet specification without warning; for life safety applications, check sensor response to gas before use.


2411261432_Amphenol-SGX-4CO-10K_C3659335.pdf
Request A Quote

Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible

You Can Upload Up To 5 Files And Each File Sized 10M Max