Product Overview
The SGX series of PS1 and PS4 Electrochemical gas sensors utilize a revolutionary 'Solid Polymer Electrolyte' technology based on catalytic reaction principles. These sensors generate a small current proportional to the target gas concentration, offering a stable, high-quality, and cost-effective manufacturing process. They are characterized by their very small size, high sensitivity, no power consumption, and low cross-sensitivity to other gases. Key applications include general gas detection, consumer markets, VOC gas detection, mobile phone noses, indoor & outdoor air quality monitoring, and low-power nose applications.
Product Attributes
- Brand: SGX
- Technology: Solid Polymer Electrolyte
- Operating Principle: Amperometric, 3-electrode
- Housing Material: PPO
- Origin: SGX Europe Sp. z o.o.
- Warranty: 12 months
- Individually calibrated: Yes (including test report)
Technical Specifications
| Specification | PS1-VOC-1000 | PS4-VOC-1000 |
|---|---|---|
| Weight | < 0.7g | < 6g |
| Sensitivity | 55 15 nA / ppm | |
| Measurement Range | 0 1000ppm | |
| Zero Current | 100 nA | |
| Maximum Overload | 2000 ppm | |
| Response Time (T50) | < 10s | |
| Response Time (T90) | < 30s | |
| Repeatability | 1% | |
| Lower Detectable Limit (LDL) | < 1 ppm | |
| Linear Range | 1000 ppm | |
| Resolution (16Bit ADC) | 0.1ppm | |
| Operating Humidity Range | 15-95% RH | |
| Pressure Range | 800 to 1200 hPA | |
| Storage Temperature | 0 to 20 | |
| Temperature Range | -40C to +55C | |
| Recommended Load Resistor | 100 | |
| Bias Voltage | 0 mV | |
| Warm Up Time | < 60 s | |
| Long-Term Drift | < 1 %/month | |
| Zero Drift in Clean Air | < 2 ppm | |
| Storage Life | 12 months | |
| Expected Lifetime | > 3 years in air | |
Features: Small size, High sensitivity, Wide temperature range, Fast response time, No electrolyte leakage, Low cost at large volumes.
Cross Sensitivity (Examples):
| Gas | Test Concentration | Sensor Reading |
|---|---|---|
| Acetaldehyde | 5ppm | 3.84ppm |
| Dimethyl Disulfide | 2ppm | 6.79ppm |
| Hydrogen Chloride | 5ppm | 0.27ppm |
| Acetic Acid | 5ppm | 1.1ppm |
| Hydrogen Cyanide | 5ppm | 4.65ppm |
| Acetylene | 5ppm | 0.36ppm |
| Ethanol | 5ppm | 1.64ppm |
| Isobutene | 5ppm | 1.83ppm |
| Acrylonitrile | 5ppm | 5ppm |
| Ethyl Mercaptan | 5ppm | 0.4ppm |
| Methanol | 5ppm | 8.97ppm |
| Ammonia | 5ppm | 5.96ppm |
| Ethylene | 5ppm | 1.5ppm |
| Methyl Mercaptan | 5ppm | 0.59ppm |
| Benzene | 5ppm | 7ppm |
| Formaldehyde | 5ppm | 1.1ppm |
| P-xylene | 5ppm | 5.29ppm |
| Trimethylamine | 5ppm | 0.59ppm |
| Butadiene | 5ppm | 0.65ppm |
| Formic Acid | 5ppm | 8.68ppm |
| Styrene | 5ppm | 5.37ppm |
| Carbon Disulfide | 5ppm | 7.5ppm |
| Carbon Monoxide | 5ppm | 3.38ppm |
| Hydrogen | 5ppm | 1.15ppm |
| Toluene | 5ppm | 0.81ppm |
Note: Performance is based on conditions at 20C, 50% RH and 1 atm, flow rate>150qcm/min, using SGX recommended circuitry. Sensor performance is temperature dependent. Do not solder to connector pins.
2411272243_Amphenol-PS1-VOC-1000_C5711030.pdf
Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible