Online Service

Online Service

Contact Person
+86 136 6733 2386
quality gas detection sensor Amphenol INIR-ME5% offering high resolution and automatic range switching capabilities factory
<
quality gas detection sensor Amphenol INIR-ME5% offering high resolution and automatic range switching capabilities factory
quality gas detection sensor Amphenol INIR-ME5% offering high resolution and automatic range switching capabilities factory
quality gas detection sensor Amphenol INIR-ME5% offering high resolution and automatic range switching capabilities factory
>
Specifications
Mfr. Part #:
INIR-ME5%
Key Attributes
Model Number: INIR-ME5%
Product Description

SGX Integrated IR (INIR) Gas Sensor

Product Overview
The SGX Integrated IR (INIR) sensor is a user-friendly digital gas sensor utilizing the latest SGX Sensortech Infrared technology. Designed for reliability and ease of implementation, it incorporates a microcontroller with an ARM7 core and embedded software to process raw signals into linear, temperature-compensated outputs proportional to gas concentration. The INIR offers triple-range detection with linear approximation for Carbon Dioxide and Methane, automatic range switching, high resolution up to 10ppm, and multi-sensor mode capabilities. It provides both analog and serial port (UART) communication, with active and reference signals monitored, and full fault diagnostics. Designed for use in hazardous areas, the INIR is certified for explosive atmospheres (EX). Its compact design and factory calibration options significantly reduce development time and expertise required for integration into gas detection instruments.

Key Features:

  • Triple Range detection with linear approximation for CO2 (0-5%) and Methane (0-5% and 0-100%).
  • Automatic switchover between detection ranges.
  • High resolution up to 10ppm.
  • Detectivity Level at 100ppm.
  • Multi-sensor mode.
  • Analog Output of gas concentration.
  • Serial port communication (UART).
  • Internal Temperature sensor.
  • Active & Reference Signals Monitored.
  • Full Faults Diagnostics & Error Generation.
  • Cyclic Redundancy Check (CRC).
  • Four Different Modes of Operation.
  • Typical low power consumption < 32mA (Average).
  • Factory calibrated for Methane or Carbon Dioxide.
  • Evaluation Kit available with PC software.
  • Easy implementation into Sensors Network.
  • Designed for use in Hazardous Areas.
  • Certified Sensor for use in Explosive Atmospheres (EX).

Recommended Applications:

  • Mining
  • Automation & Control
  • Indoor Air Quality
  • Industrial Health & Safety

Product Attributes

  • Brand: SGX Sensortech
  • Origin: Poland
  • Body Material: Stainless Steel
  • Certifications: ATEX, IECEx (II 2G Ex db IIC Gb Ta -40oC to +75oC)
  • RoHS Compliance: Yes
  • WEEE Directive: Component classification

Technical Specifications

Specification Min Typical Max Notes
Absolute Maximum Ratings
Supply Voltage 3.2 VDC 3.3 VDC 5.25 VDC
Average Current Consumption 30mA 32mA 35 mA *Inrush Current can be up to 65mA
Logic Outputs Level
LOW Voltage Level (VOL) 0.6V Maximum 1.6mA source current
HIGH Voltage Level (VOH) 2.0V Minimum
Logic Inputs Level
LOW Voltage Level (VINL) 0.4V Maximum
HIGH Voltage Level (VINH) 2.0V Minimum
Humidity
Operating Humidity 0% 50% 99% Condensation may affect performance. Algorithms implemented to minimize effects.
Storage Humidity 0% 50% 90%
Temperature
Operating Temperature -40 C +20 C +75 C
Storage Temperature -20 C +20 C +55 C
Temp. Cycle Limits 0.8C/min 1.3C/min
Pressure
Operating Pressure 80kPa 120kPa Compensation will be required.
Storage Pressure 80kPa 120kPa
Performance
DAC Resolution 12-Bit at 0.0-2.5 Volts DC Max Scalable according to Gas Conc.
Digital Signal Format 8 data bits, 1 stop bit, no parity
Baud Rate 38400 (default) 115200, 19200, 9600 supported
Dimensions (mm)
Diameter (D) 19.9 20 20.1
Height (H) 16.50 16.60 16.70
Pins Height (pH) 4.0 4.8 5.6
Weight 25 g 29 g 33 g
Pin Configuration
Pin 1 TXD (Data transmitted from the Integrated IR)
Pin 2 +VCC (3.2 Volts 5.25 Volts DC input)
Pin 3 GND (0 Volts reference)
Pin 4 RXD (Data received by the Integrated IR)
Pin 5 OUT (Analog Output)
Models / Calibration
Ordering Code Methane Detection Carbon Dioxide Detection Standard Calibration
INIR-ME100% YES NO 0-100%
INIR-ME5% YES NO 0-5%
INIR-CD5% NO YES 0-5%
INIR-EK4 Evaluation Kit (without sensor)

Design Considerations

  • Warm-Up Time: 45 seconds after power ON or mode change. Data is not valid during this period.
  • Calibration: Factory calibrated; recommended calibration gases and procedures detailed in Application Note 1.
  • Gas Flow Rate: Recommended 450 500 cc/min for evaluation.
  • Digital Interface: Requires MCU or PC for reading digital output. Evaluation software compatible with Windows OS.
  • Faults Monitoring: Error monitoring and fault generation transmitted via UART every second.
  • Analogue Output: Updated every one second, directly related to concentration.
  • Condensation, Dust & Extreme Conditions: High corrosion resistance, temperature compensated. Condensation compensation algorithm implemented. Dust filters recommended for dusty environments.
  • Pressure Compensation: Required. Re-zeroing under operating conditions is recommended.
  • Ranges: Automatic switchover between LOW (0.0%-1.0%), MID (1.0%-4.0%), HIGH (4.0% and above).

Typical Performance Characteristics (at 20C, 10% RH, 101kPa, 500-1000 ml/min Gas Flow)

Test INIR-ME100%, INIR-ME5% INIR-CD5.0%
Stabilisation or Warm-up Time (EN) 0%v.v 0.1%Vol in 45 seconds 0%v.v 0.01%Vol in 45 seconds
Calibration Curve (EN) / Basic Error (AQ) 0 to 100% of full range -> 0.06%v.v or 6% of Reading 0 to 5%v.v -> 0.06%v.v or 6% of Reading
Short Term Stability (EN) of Displayed Value (AQ) 0%v.v = 0.005%v.v; 5%v.v = 0.1%v.v; 100%v.v = 1%v.v*3 0%v.v = 0.002%v.v; 5%v.v = 0.05%v.v
Minimum Resolution (AQ) 0 to 5%v.v -> 0.002%v.v; 5 to 100%v.v -> 0.1%v.v*3 0 to 2%v.v -> 0.004%v.v; 2 to 5%v.v -> 0.01%v.v
Long Term Stability (EN) / Working Stability (AQ) 0%v/v = 0.01%v.v / Month; 5%v/v = 0.1%v.v / Month; 100%v/v = 1.5%v.v / Month*3 0%v/v = 0.05%v.v / Month; 2%v/v = 0.05%v.v / Month; 5%v/v = 0.1%v.v / Month
Temperature Error (Compensation) (-40C to +75C, rel. to 20C) 0%v.v to 5%v.v = 0.05%v/v; 5%v.v to 20%v.v = 0.2%v.v*3; 20%v.v to 100%v.v = 2%v.v*3 0%v/v to 2%v.v = 0.01%v.v; 2%v/v to 4%v.v = 0.02%v.v; 4%v.v to 5%v.v = 0.05%v.v
Humidity Error (10%RH to 90%RH, rel. to 45%RH) 0%v.v = 0.05%v.v; 5%v.v = 0.1%v.v; 100%v.v = 1.5%v.v*3 0%v/v = 0.01%v.v; 5%v/v = 0.05%v.v
Response Time*2 (without dust filter) Typ. T90 18 sec, Max T90 30 sec Typ. T90 18 sec, Max T90 30 sec
Power Supply Variations (5% of Nominal Voltage) Performance not affected if DC regulated voltage is provided.
Power Supply Rejection Ratio (PSRR) (5% of Nominal Voltage) 1 MHz -> 50 dB, 100 kHz -> 68 dB, 10 kHz -> 88 dB
Temperature Cycling/Ramping Drift (Max at 1.3C/min.) 0%v/v = 0.05%v.v; 5%v/v = 0.2%v.v; 100%v/v = 3%v.v*3 0%v/v = 0.05%v.v; 2%v/v = 0.1%v.v; 5%v/v = 0.25%v.v
Thermal Shock Drift 0%v/v = 0.05%v.v (max) 0%v/v = 0.05%v.v (max)
Uncertainty Error of Calibration 0.15%
Error of the Actual Reading 0.15%

Warranty & Warning

  • Warranty: 3 years from purchase date, subject to use according to datasheet and Application Note. Void if used outside specified conditions.
  • Conditions that void warranty: Water ingress, vandalism, label alteration, overvoltage/overcurrent, direct soldering, physical impact, opening/breaking the sensor, exposure to high dust/corrosive gases/acidic environments, painting/marking, custom modification, cleaning with acid. Recalibration voids calibration certificate, not warranty.
  • ESD Precaution: Device is ESD sensitive. Proper precautions should be taken.
  • Handling: Do not drop, avoid mechanical force, do not immerse in water, do not solder directly.
  • Operation: Power down instrument before plugging/unplugging sensor.

2411261541_Amphenol-INIR-ME5-_C1139050.pdf
Request A Quote

Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible

You Can Upload Up To 5 Files And Each File Sized 10M Max