Product Overview
The SGX series of PS1 and PS4 Electrochemical gas sensors utilize a revolutionary 'Solid Polymer Electrolyte' technology based on catalytic reaction principles. These sensors generate a small current proportional to the target gas concentration, offering a stable, high-quality, and cost-effective manufacturing process. They are characterized by their very small size, high sensitivity, low power consumption, and minimal cross-sensitivity to other gases. Key applications include ambient monitoring, sensitive leak detection, battery production, semiconductor manufacturing, data center protection, and propellant detection.
Product Attributes
- Brand: SGX
- Technology: Solid Polymer Electrolyte (SPE)
- Operating Principle: Amperometric, 3-electrode
- Housing Material: PPO
- Origin: Poland (SGX Europe Sp. z o.o.)
- Warranty: 12 months
- Expected Lifetime: > 5 years in air
Technical Specifications
| Model | PS1-H2-1000 | PS4-H2-1000 |
|---|---|---|
| Sensitivity | 11 ± 3 nA / ppm | |
| Measurement Range | 0 1000 ppm | |
| Zero Current | ± 100 nA | |
| Maximum Overload | 2000 ppm | |
| Response Time | T50 < 10s, T90 < 30s | |
| Repeatability | 1% | |
| Lower Detectable Limit (LDL) | ≤ 2 ppm | |
| Linear Range | 1000 ppm | |
| Resolution (16Bit ADC) | 0.1ppm | |
| Operating Humidity Range | 15-95% RH | |
| Pressure Range | 800 to 1200 hPA | |
| Storage Temperature | 0 to 20°C | |
| Temperature Range | -40°C to +55°C | |
| Recommended Load Resistor | 100 Ω | |
| Bias Voltage | 0 mV | |
| Warm Up Time | < 60 s | |
| Long-Term Drift | < 1 %/month | |
| Zero Drift in Clean Air | < 10 ppm | |
| Storage Life | 12 months | |
| Weight | < 0.7g | < 6g |
Important Notes
- All performance is based on conditions at 20°C, 50% RH and 1 atm, flow rate>150qcm/min, using SGX recommended circuitry.
- Sensor performance is temperature dependent; please contact SGX for temperature performance other than 20°C.
- Do not solder to the connector pins as this may damage the sensor and thereby invalidate the warranty.
- Details on recommended connector pins can be found in the Frequently Asked Questions within the Gas Sensor section of the SGX website.
- The cross-sensitivity factors may vary due to different sensors and service life; please refer to the actual test results.
- The cross-sensitivity table is not complete for all gases; for other gases, please contact SGX.
- Exposure to high concentrations of solvent vapours should be avoided during storage, fitting, and operation.
- When using sensors on printed circuit boards (PCBs), degreasing agents should be used prior to the sensor being fitted.
- For applications where life safety is a performance requirement, it is recommended that all sensors and instruments using these sensors are checked for response to gas before use.