quality High Precision Amphenol PS4-H2-1000 Electrochemical Sensor with Solid Polymer Electrolyte Technology factory
<
quality High Precision Amphenol PS4-H2-1000 Electrochemical Sensor with Solid Polymer Electrolyte Technology factory
>
Specifications
Measurement Range:
1.2bar~800mbar
Operating Temperature:
-40℃~+55℃
Mfr. Part #:
PS4-H2-1000
Key Attributes
Model Number: PS4-H2-1000
Product Description

Product Overview

The SGX series of PS1 and PS4 Electrochemical gas sensors utilize a revolutionary 'Solid Polymer Electrolyte' technology based on catalytic reaction principles. These sensors generate a small current proportional to the target gas concentration, offering a stable, high-quality, and cost-effective manufacturing process. They are characterized by their very small size, high sensitivity, low power consumption, and minimal cross-sensitivity to other gases. Key applications include ambient monitoring, sensitive leak detection, battery production, semiconductor manufacturing, data center protection, and propellant detection.

Product Attributes

  • Brand: SGX
  • Technology: Solid Polymer Electrolyte (SPE)
  • Operating Principle: Amperometric, 3-electrode
  • Housing Material: PPO
  • Origin: Poland (SGX Europe Sp. z o.o.)
  • Warranty: 12 months
  • Expected Lifetime: > 5 years in air

Technical Specifications

Model PS1-H2-1000 PS4-H2-1000
Sensitivity 11 ± 3 nA / ppm
Measurement Range 0 1000 ppm
Zero Current ± 100 nA
Maximum Overload 2000 ppm
Response Time T50 < 10s, T90 < 30s
Repeatability 1%
Lower Detectable Limit (LDL) ≤ 2 ppm
Linear Range 1000 ppm
Resolution (16Bit ADC) 0.1ppm
Operating Humidity Range 15-95% RH
Pressure Range 800 to 1200 hPA
Storage Temperature 0 to 20°C
Temperature Range -40°C to +55°C
Recommended Load Resistor 100 Ω
Bias Voltage 0 mV
Warm Up Time < 60 s
Long-Term Drift < 1 %/month
Zero Drift in Clean Air < 10 ppm
Storage Life 12 months
Weight < 0.7g < 6g

Important Notes

  • All performance is based on conditions at 20°C, 50% RH and 1 atm, flow rate>150qcm/min, using SGX recommended circuitry.
  • Sensor performance is temperature dependent; please contact SGX for temperature performance other than 20°C.
  • Do not solder to the connector pins as this may damage the sensor and thereby invalidate the warranty.
  • Details on recommended connector pins can be found in the Frequently Asked Questions within the Gas Sensor section of the SGX website.
  • The cross-sensitivity factors may vary due to different sensors and service life; please refer to the actual test results.
  • The cross-sensitivity table is not complete for all gases; for other gases, please contact SGX.
  • Exposure to high concentrations of solvent vapours should be avoided during storage, fitting, and operation.
  • When using sensors on printed circuit boards (PCBs), degreasing agents should be used prior to the sensor being fitted.
  • For applications where life safety is a performance requirement, it is recommended that all sensors and instruments using these sensors are checked for response to gas before use.

2411272248_Amphenol-PS4-H2-1000_C6358707.pdf