Online Service

Online Service

Contact Person
+86 136 6733 2386
quality VOC sensor Amphenol PS1-VOC-10 with solid polymer electrolyte and three electrode amperometric design factory
<
quality VOC sensor Amphenol PS1-VOC-10 with solid polymer electrolyte and three electrode amperometric design factory
>
Specifications
Measurement Range:
1.2bar~800mbar
Operating Temperature:
-40℃~+55℃
Mfr. Part #:
PS1-VOC-10
Key Attributes
Model Number: PS1-VOC-10
Product Description

Product Overview

The SGX series of PS1 and PS4 VOC gas sensors utilize a revolutionary 'Solid Polymer Electrolyte' technology based on catalytic reaction principles. These sensors generate a small current proportional to the target gas concentration, offering a stable, high-quality, and cost-effective manufacturing process. They are characterized by their very small size, high sensitivity, zero power consumption, and low cross-sensitivity to other gases. Ideal for general gas detection, consumer markets, VOC gas detection, mobile phone noses, and indoor/outdoor air quality monitoring, these sensors provide fast response times and are individually calibrated with a test report.

Product Attributes

  • Brand: SGX
  • Technology: Solid Polymer Electrolyte
  • Operating Principle: Amperometric, 3-electrode
  • Housing Material: PPO
  • Origin: SGX Europe Sp. z o.o., Poland
  • Warranty: 12 months
  • Storage Life: 12 months
  • Expected Lifetime: > 3 years in air

Technical Specifications

Model PS1-VOC-10 PS4-VOC-10 Specification Value
Weight < 0.7g < 6g
Sensitivity 55 15 nA / ppm
Measurement Range 0 10ppm
Zero Current 100 nA
Maximum Overload 100 ppm
Response Time T50 < 10s, T90 < 30s
Repeatability 1%
Lower Detectable Limit (LDL) < 1 ppm
Linear Range 10 ppm
Resolution (16Bit ADC) 0.01ppm
Operating Humidity Range 15-95% RH
Pressure Range 800 to 1200 hPA
Storage Temperature 0 to 20
Temperature Range -40C to +55C
Recommended Load Resistor 100
Bias Voltage 0 mV
Warm Up Time < 60 s
Long-Term Drift < 1 %/month
Zero Drift in Clean Air < 2 ppm
Storage conditions 0-20 C

Important Notes: All performance is based on conditions at 20C, 50% RH and 1 atm, flow rate>150qcm/min, using SGX recommended circuitry. Sensor performance is temperature dependent; please contact SGX for temperature performance other than 20C. Do not solder to the connector pins as this may damage the sensor and thereby invalidate the warranty. Details on recommended connector pins can be found in the Frequently Asked Questions within the Gas Sensor section of the SGX website.

Features: Small size, High sensitivity, Wide temperature range, Fast response time, No electrolyte leakage, Low cost at large volumes, Individually calibrated (including test report).

Key applications: General Gas Detection, Consumer Market, VOC Gas Detection, Mobile Phone Nose, Indoor & Outdoor Air Quality, Low Power Nose.

Cross Sensitivity (Sample Data):

Gas Formula Test Concentration Sensor Reading
Acetaldehyde C2H4O 5ppm 3.84ppm
Dimethyl Disulfide C2H6S2 2ppm 6.79ppm
Hydrogen Chloride HCL 5ppm 0.27ppm
Acetic Acid CH3COOH 5ppm 1.1ppm
Unsaturated hydrocarbons C2H2 5ppm 4.65ppm
Hydrogen Cyanide HCN 3.84ppm 0.36ppm
Acetylene C2H2 6.79ppm 1.64ppm
Ethanol C2H6O 0.27ppm 1.83ppm
Isobutene C4H8 5ppm 5ppm
Acrylonitrile C3H3N 5ppm 0.4ppm
Ethyl Mercaptan C2H6S 5ppm 8.97ppm
Methanol CH4O 5ppm 5.96ppm
Ammonia NH3 5ppm 1.5ppm
Ethylene C2H4 5ppm 0.59ppm
Methyl Mercaptan C3H4S 5ppm 7ppm
Benzene C6H6 5ppm 1.1ppm
Formaldehyde HCHO 5ppm 5.29ppm
P-xylene C8H10 5ppm 0.59ppm
Trimethylamine C3H9N 5ppm 0.65ppm
Butadiene C4H6 5ppm 8.68ppm
Formic Acid HCOOH 5ppm 5.37ppm
Styrene C8H8 0.5ppm 7.5ppm
Carbon Disulfide CS2 5ppm 1.23ppm
Carbon Monoxide CO 5ppm 3.38ppm
Hydrogen H2 5ppm 1.15ppm
Toluene C7H8 5ppm 0.81ppm

Note on Cross Sensitivity: The above interference factors may vary due to different sensors and service life; please refer to the actual test results. This table is not complete for all cross gases; for other gases, please contact us.

Disclaimer: SGX Europe Sp. z o.o. reserves the right to change design features and specifications without prior notification. We do not accept any legal responsibility for customer applications of our sensors. SGX Europe Sp. z o.o. accepts no liability for any consequential losses, injury or damage resulting from the use of this document, the information contained within or from any omissions or errors herein. This document does not constitute an offer for sale and the data contained is for guidance only and may not be taken as warranty. Any use of the given data must be assessed and determined by the user thereof to be in accordance with federal, state and local laws and regulations. All specifications outlined are subject to change without notice. SGX Europe Sp. z o.o. sensors are designed to operate in a wide range of harsh environments and conditions. However, it is important that exposure to high concentrations of solvent vapours is to be avoided, both during storage, fitting into instruments and operation. When using sensors on printed circuit boards (PCBs), degreasing agents should be used prior to the sensor being fitted. SGX Europe Sp. z o.o. makes every effort to ensure the reliability of its products. Where life safety is a performance requirement of the product, we recommend that all sensors and instruments using these sensors are checked for response to gas before use.


2411272306_Amphenol-PS1-VOC-10_C6629194.pdf

Request A Quote

Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible

You Can Upload Up To 5 Files And Each File Sized 10M Max