Specifications
Measurement Range:
800mbar~1200mbar
Operating Temperature:
-20℃~+50℃
Mfr. Part #:
SGX-7CL2
Key Attributes
Model Number: SGX-7CL2
Product Description

Product Overview

The SGX-7CL2 is an industrial Chlorine (CL2) gas sensor designed for reliable detection in various environments. It offers a measurement range of 0-20 ppm with a T90 response time of less than 60 seconds. The sensor is characterized by its linear output and good repeatability, making it suitable for applications requiring accurate CL2 monitoring. It is designed for long-term operation with an expected life of over 12 months in air and features intrinsic safety data for enhanced operational safety.

Product Attributes

  • Brand: SGX Sensortech
  • Model: SGX-7CL2
  • Compliance: RoHS compliant

Technical Specifications

Specification Value
Temperature Range -20C to +50C
Pressure Range 800 to 1200 mbar
Operating Humidity Range 15% to 90% RH
Expected Operating Life > 12 months in air
Output Signal 1000 300 nA / ppm
Typical Baseline Range (pure air) 0.2ppm CL2 equivalent
T90 Response Time < 60 seconds
Measurement Range 0 - 20 ppm
Maximum Overload 250 ppm
Linearity Linear
Repeatability < 2% CL2 equivalent
Recommended Load Resistor 33 ohms
Resolution (Electronics dependent) 0.1 ppm typical
Long Term Output Drift < 20% per annum Max at 150ppm
Max o/c Voltage 1.3 V
Max s/c Current <1.0 A
Recommended Storage Temp 0C to 20C
Cross Sensitivity - Carbon Monoxide (300 ppm) 0 ppm
Cross Sensitivity - Sulfur Dioxide (20 ppm) 0 ppm
Cross Sensitivity - Nitric Oxide (50 ppm) 0 ppm
Cross Sensitivity - Hydrogen Sulfide (15 ppm) -5 to 0 ppm
Cross Sensitivity - Nitrogen Dioxide (5 ppm) 4 to 5 ppm

Important Notes:

  • Do not glue or solder to the connector pins; use PSB sockets.
  • Refer to the SGX website for recommended connector pins.
  • Performance specifications are based on 20C, 50% RH, 101kPa.
  • Cross sensitivity data is for information only; calibration with target gas is recommended.
  • Sensors may respond to gases other than those listed.
  • Cross sensitivities may fluctuate.
  • Avoid exposure to high concentrations of solvent vapours.
  • Use degreasing agents prior to fitting sensors on PCBs.
  • Electrochemical gas sensors can potentially fail without warning. For life safety applications, check sensor response to gas before use.
  • SGX Europe Sp. z o.o. reserves the right to make product changes without notice.
  • The data is for guidance only and does not constitute a specification or offer for sale.