quality Compact Electrochemical Oxygen Sensor Amphenol PS4-O2-25% Designed for Medical and Combustion Control factory
<
quality Compact Electrochemical Oxygen Sensor Amphenol PS4-O2-25% Designed for Medical and Combustion Control factory
>
Specifications
Operating Temperature:
-20℃~+55℃
Mfr. Part #:
PS4-O2-25%
Key Attributes
Model Number: PS4-O2-25%
Product Description

Product Overview

The SGX series of PS1 and PS4 Electrochemical gas sensors utilize a revolutionary Solid Polymer Electrolyte technology based on catalytic reaction principles. These sensors generate a small current proportional to the target gas concentration, offering a stable, high-quality, and cost-effective manufacturing process. They are characterized by their very small size, high sensitivity, zero power consumption, and low cross-sensitivity to other gases. Ideal for medical, industrial, combustion control, food industry, and general gas detection applications.

Product Attributes

  • Brand: SGX
  • Technology: Solid Polymer Electrolyte
  • Housing Material: PPO
  • Certifications: Lead free

Technical Specifications

Specification PS1-O2-25% PS4-O2-25%
Sensitivity 0.2 0.03 nA / ppm 0.2 0.03 nA / ppm
Measurement Range 0 25 %vol 0 25 %vol
Zero Current 40-60 A 40-60 A
Maximum Overload 30 %vol 30 %vol
Response Time (T50) < 5s < 5s
Response Time (T90) < 10s < 10s
Lower Detectable Limit (LDL) 0.5 %vol 0.5 %vol
Resolution (16Bit ADC) 0.01 %vol 0.01 %vol
Operating Humidity Range 15-95% RH
Pressure Range 800 to 1200 hPA
Storage Temperature 0 to 20
Temperature Range -20C to +55C
Operating Principle Amperometric, 3-electrode
Recommended Load Resistor 220
Bias Voltage -400 to -600 mV
Warm Up Time < 15 min
Long-Term Drift < 1 %/month
Zero Drift in Clean Air < 0.2 %vol
Storage Life 12 months
Expected Lifetime > 5 years
Warranty 12 months
Weight < 0.7g < 6g

Important Notes & Handling Precautions

  • All performance is based on conditions at 20C, 50% RH and 1 atm, flow rate>150qcm/min, using SGX recommended circuitry.
  • Sensor performance is temperature dependent; contact SGX for performance outside 20C.
  • Do not solder to the connector pins as this may damage the sensor and invalidate the warranty. Use PCB sockets and firmly push-fit the sensor.
  • Exposure to high concentrations of solvent vapours should be avoided during storage, fitting, and operation.
  • When using sensors on printed circuit boards (PCBs), degreasing agents should be used prior to sensor fitting.
  • For life safety applications, it is recommended that all sensors and instruments are checked for response to gas before use.

Cross Sensitivity

Note: Interference factors may vary. Refer to actual test results. This table is not exhaustive; contact SGX for other gases.

Gas Formula Test Concentration Sensor Reading
Ammonia NH3 20ppm 0ppm
Carbon Dioxide CO2 5000ppm 0ppm
Carbon Monoxide CO 1ppm 0ppm
Chlorine CL2 50ppm 0ppm
Hydrogen Cyanide HCN 1%vol 0ppm
Hydrocarbons (unsaturated) C3H8O 10ppm 0ppm
Hydrogen H2 100ppm 0ppm
Isopropanol 1000ppm 0ppm
Nitric Oxide NO 25ppm 10ppm
Nitrogen Dioxide NO2 0.5ppm 20ppm
Ozone O3 0ppm 0ppm
Sulphur Dioxide SO2 0ppm 0ppm