Online Service

Online Service

Contact Person
+86 136 6733 2386
quality Amphenol MICS VZ 89TE integrated sensor detects total VOCs and CO2 equivalent for indoor air systems factory
<
quality Amphenol MICS VZ 89TE integrated sensor detects total VOCs and CO2 equivalent for indoor air systems factory
>
Specifications
Mfr. Part #:
MICS-VZ-89TE
Key Attributes
Model Number: MICS-VZ-89TE
Product Description

Product Overview

The MiCS-VZ-89TE is an integrated sensor board designed for Indoor Air Quality (IAQ) monitoring. It leverages state-of-the-art MOS sensor technology and intelligent detection algorithms to monitor total Volatile Organic Compounds (tVOCs) and Carbon Dioxide equivalent (CO2eq) variations in confined spaces such as meeting rooms and vehicle cabins. The dual signal output (PWM and I2C) enables on-demand ventilation control, leading to energy savings and reduced cost of ownership. This sensor is calibration-free, offers low power consumption, a wide VOC detection range, high sensitivity, and robust resistance to shocks and vibrations.

Product Attributes

  • Brand: SGX Sensortech
  • Origin: Switzerland
  • Product Name: MiCS-VZ-89TE
  • Detectable Gases: Volatile Organic Compounds (VOCs), Equivalent Carbon Dioxide (CO2(equiv))

Technical Specifications

Specification Details
Detection Method Semiconductor gas sensor, detecting a wide range of VOCs
Monitoring Range (CO2eq) 400-2000 ppm equivalent CO2
Monitoring Range (tVOCs) 0-1000 ppb isobutylene equivalent tVOCs
PWM Output Pin 1: TTL output 30Hz +/-1%, Range 595%, duty cycle 3.3V. Use a pull-up resistance (typ. 10kOhms for 3.3V) between Pin 1 and Pin 6.
I2C Output Pin 2 and 4: Pull-up of 4.7 kOhms on master SDA and SCL.
Response Time (tVOC) Equivalent to conventional NDIR-CO2 sensors < 5 seconds
Refresh Output Frequency 1 Hz
Supply Voltage 3.3V DC regulated +/- 5%
Operating Power 125 mW
Warm-up Time 15 min
Operating Temperature 0C to 50C
Operating Humidity 0%RH to 95%RH (non-condensing)
Storage Temperature -40C to 80C
Storage Humidity 0%RH to 95%RH (non-condensing)
Power-on Self-Test 2 seconds. Provides "Failed Diagnostic Level" or multiplexed PWM output for CO2eq and VOC levels.
I2C Data Output Format D1: tVOC [ppb] (13-242), D2: CO2eq [ppm] (13-242), D3-D5: Resistor value, D6: Status, D7: CRC.
Mounting PCB, mountable with M2.5 screw. Connections via soldering on card edge.
Pin Connections 1: PWM OUT, 2: SCL, 3: GND, 4: SDA, 5: NC, 6: + 3.3V