Product Overview
The SGX series of PS1 and PS4 Electrochemical gas sensors, utilizing revolutionary 'Solid Polymer Electrolyte' technology, offer a stable, high-quality, and cost-effective solution for measuring carbon monoxide. Based on catalytic reaction principles, these sensors generate a small current proportional to the target gas concentration. They are characterized by their small size, high sensitivity, low power consumption, and minimal cross-sensitivity to other gases. Key applications include TLV monitoring, environmental air monitoring, parking garages, steel industry, oil & petrochemical industry, and leakage detection.
Product Attributes
- Brand: SGX
- Technology: Solid Polymer Electrolyte
- Operating Principle: Amperometric, 3-electrode
- Housing Material: PPO
- Origin: Poland (SGX Europe Sp. z o.o.)
Technical Specifications
| Specification | PS1-CO-100 | PS4-CO-100 |
|---|---|---|
| Sensitivity | 25 10 nA / ppm | 25 10 nA / ppm |
| Measurement Range | 0 100 ppm | 0 100 ppm |
| Zero Current | 100 nA | 100 nA |
| Maximum Overload | 1000 ppm | 1000 ppm |
| Response Time (T50) | < 10s | < 10s |
| Response Time (T90) | < 30s | < 30s |
| Repeatability | < 1% | < 1% |
| Lower Detectable Limit (LDL) | 2 ppm | 2 ppm |
| Linear Range | 100 ppm | 100 ppm |
| Resolution (16Bit ADC) | <0.1ppm | <0.1ppm |
| Operating Humidity Range | 15-95% RH | 15-95% RH |
| Pressure Range | 800 to 1200 hPA | 800 to 1200 hPA |
| Storage Temperature | 0 to 20 | 0 to 20 |
| Temperature Range | -40C to +55C | -40C to +55C |
| Recommended Load Resistor | 100 | 100 |
| Bias Voltage | 0 mV | 0 mV |
| Warm Up Time | < 60 s | < 60 s |
| Long-Term Drift | < 1 %/month | < 1 %/month |
| Zero Drift in Clean Air | < 2 ppm | < 2 ppm |
| Storage Life | 12 months | 12 months |
| Expected Lifetime | > 5 years in air | > 5 years in air |
| Warranty | 12 months | 12 months |
| Weight | < 0.7g | < 6g |
Features
- Small size
- Fast response time
- Wide temperature range
- Extreme linear response up to high concentration
- No electrolyte leakage
- High sensitivity
- Excellent sensitivity at low temperatures
- Stable zero point
Important Notes
- All performance is based on conditions at 20C, 50% RH and 1 atm, flow rate>150qcm/min, using SGX recommended circuitry.
- Sensor performance is temperature dependent; please contact SGX for temperature performance other than 20C.
- Do not solder to the connector pins as this may damage the sensor and thereby invalidate the warranty.
- Details on recommended connector pins can be found in the Frequently Asked Questions within the Gas Sensor section of the SGX website.
- It is important that exposure to high concentrations of solvent vapours is to be avoided, both during storage, fitting into instruments and operation.
- When using sensors on printed circuit boards (PCBs), degreasing agents should be used prior to the sensor being fitted.
- Where life safety is a performance requirement of the product, we recommend that all sensors and instruments using these sensors are checked for response to gas before use.
Cross Sensitivity
| Gas | Formula | Test Concentration | Sensor Reading |
|---|---|---|---|
| Alcohols | R-OH | 1000ppm | n.e |
| Ammonia | NH3 | 50ppm | 0ppm |
| Carbon Dioxide | CO2 | 1000ppm | 1ppm |
| Chlorine | CL2 | 0ppm | 0ppm |
| Ethylene | C2H4 | 10ppm | 50ppm |
| Hydrogen Cyanide | HCN | 0ppm | 0ppm |
| Hydrogen | H2 | 100ppm | 20ppm |
| Hydrogen Sulphide | H2S | 50ppm | 0ppm |
| Isopropanol | C3H7OH | 1000ppm | 0ppm |
| Methanal | CH4 | 1%vol | 0ppm |
| Nitric Oxide | NO | 25ppm | 0ppm |
| Nitrogen Dioxide | NO2 | 10ppm | 0ppm |
| Sulphur Dioxide | SO2 | 10ppm | 0ppm |
Note: 1) The above interference factors may vary due to different sensors and service life, please refer to the actual test results. 2) This table is not complete for all cross gases, other gas please contact with us.
Key Applications
- TLV Monitoring
- Environmental air monitoring
- Parking Garages
- Steel Industry
- Oil & Petrochemical Industry
- Leakage Detection
Disclaimer
SGX Europe Sp. z o.o. reserves the right to change design features and specifications without prior notification. We do not accept any legal responsibility for customer applications of our sensors. SGX Europe Sp. z o.o. accepts no liability for any consequential losses, injury or damage resulting from the use of this document, the information contained within or from any omissions or errors herein. This document does not constitute an offer for sale and the data contained is for guidance only and may not be taken as warranty. Any use of the given data must be assessed and determined by the user thereof to be in accordance with federal, state and local laws and regulations. All specifications outlined are subject to change without notice.