Online Service

Online Service

Contact Person
+86 136 6733 2386
quality Hydrogen Sulfide Sensor Amphenol PS1 H2S 500 Solid Polymer Electrolyte for Biogas and Leak Detection factory
<
quality Hydrogen Sulfide Sensor Amphenol PS1 H2S 500 Solid Polymer Electrolyte for Biogas and Leak Detection factory
>
Specifications
Measurement Range:
1.2bar~800mbar
Operating Temperature:
-40℃~+55℃
Mfr. Part #:
PS1- H2S-500
Key Attributes
Model Number: PS1- H2S-500
Product Description

SGX Solid Polymer Electrolyte Gas Sensors - Hydrogen Sulfide (H2S)

Product Overview
SGX Solid Polymer Electrolyte (SPE) gas sensors, specifically the PS1 and PS4 series for Hydrogen Sulfide (H2S), utilize a revolutionary SPE technology based on catalytic reaction. These sensors generate a small current proportional to the target gas concentration, offering a stable, high-quality, and cost-effective solution. Their small size, high sensitivity, and lack of power consumption, coupled with very low cross-sensitivity, make them ideal for various applications. Key benefits include a wide temperature range, fast response time, no electrolyte leakage, extreme linearity up to high concentrations, excellent sensitivity at low temperatures, and low cost at large volumes. Each sensor is individually calibrated with a test report.

Key Applications

  • Biogas Applications
  • Water Treatment Plants
  • Leak detection
  • Portable & Fixed Point Applications

Product Attributes

  • Brand: SGX
  • Technology: Solid Polymer Electrolyte (SPE)
  • Housing Material: PPO
  • Origin: Poland (SGX Europe Sp. z o.o.)
  • Calibration: Individually calibrated (including test report)

Technical Specifications

Specification PS1-H2S-500 PS4-H2S-500
Sensitivity 90 ± 20 nA/ppm 90 ± 20 nA/ppm
Measurement Range 0 500 ppm 0 500 ppm
Zero Current ± 20 nA ± 20 nA
Maximum Overload 1000 ppm 1000 ppm
Response Time (T50) < 10s < 10s
Response Time (T90) < 30s < 30s
Repeatability < 1% < 1%
Lower Detectable Limit (LDL) ≤ 2 ppm ≤ 2 ppm
Linear Range 500 ppm 500 ppm
Resolution (16Bit ADC) 0.1ppm 0.1ppm
Operating Humidity Range 15-95% RH
Pressure Range 800 to 1200 hPa
Storage Temperature 0 to 20°C
Temperature Range -40°C to +55°C
Operating Principle Amperometric, 3-electrode
Recommended Load Resistor 100 Ω
Bias Voltage 0 mV
Warm Up Time < 60 s
Long-Term Drift < 1 %/month
Zero Drift in Clean Air < 2 ppm
Storage Life 12 months
Expected Lifetime > 3 years in air
Warranty 12 months
Weight < 0.7g < 6g

Cross Sensitivity

Gas Formula Test Concentration Sensor Reading (PS1/PS4)
Ammonia NH3 50ppm n.e
Carbon Dioxide CO2 1000ppm 0ppm
Carbon Monoxide CO 50ppm 0ppm
Methane CH4 1%vol 3ppm
Hydrogen H2 50ppm 0ppm
Hydrogen Cyanide HCN 3ppm 0ppm
Isopropanol C3H7OH 100ppm 10ppm
Nitric Oxide NO 3ppm 0ppm
Sulphur Dioxide SO2 1000ppm n.e
Chlorine CL2 25ppm -1.5ppm

Note: Interference factors may vary. Refer to actual test results. This table is not exhaustive; contact SGX for other cross gases.

Important Notes

  • Performance is based on conditions at 20°C, 50% RH, 1 atm, flow rate >150 qcm/min, using SGX recommended circuitry.
  • Sensor performance is temperature dependent; contact SGX for data at temperatures other than 20°C.
  • Do not solder to connector pins; this may damage the sensor and invalidate the warranty.
  • Recommended connector pin details are available in the SGX website FAQ.
  • Avoid exposure to high concentrations of solvent vapors during storage, fitting, and operation.
  • When using sensors on PCBs, use degreasing agents prior to fitting.
  • For life safety applications, check sensor response to gas before use.

Disclaimer: SGX Europe Sp. z o.o. reserves the right to change specifications without prior notification. No legal responsibility is accepted for customer applications. Liability for consequential losses, injury, or damage is excluded. Data is for guidance only and not a warranty. All specifications are subject to change.


2411272248_Amphenol-PS1--H2S-500_C5848064.pdf
Request A Quote

Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible

You Can Upload Up To 5 Files And Each File Sized 10M Max