Product Overview
The EC4-500-ETO is an industrial Ethylene Oxide (ETO) sensor designed for detecting ETO in various industrial environments. It offers a measurement range of 0-500 ppm with a T90 response time of 120 seconds. The sensor operates within a temperature range of -20C to +50C and a pressure range of 900 to 1100 mbar, with an operating humidity range of 15% to 90% RH. It is recommended for applications where ETO monitoring is critical. The sensor has an expected operating life of 24 months in air and features a long-term sensitivity drift of less than 2% signal per month.
Product Attributes
- Brand: SGX Sensortech
- Model: EC4-500-ETO
- Type: Industrial Ethylene Oxide Sensor
- Origin: SGX Europe Sp. Z o.o.
Technical Specifications
| Specification | Value |
|---|---|
| Measurement Range | 0-500 ppm |
| T90 Response Time | 120 seconds |
| Operating Temperature Range | -20C to +50C |
| Pressure Range | 900 to 1100 mbar |
| Operating Humidity Range | 15% to 90% RH |
| Expected Operating Life | 24 months in air |
| Long Term Sensitivity Drift | < 2% signal per month |
| Sensitivity | 58nA 33nA/ppm |
| Typical Baseline Range (pure air) | -0.2 to 2.5 A |
| Baseline Drift | 0 to 25 ppm equivalent |
| Linearity | Linear |
| Resolution (Electronics dependent) | 10 ppm |
| Bias Voltage | +300mV |
| Recommended Storage Temp | 0C to 20C |
Cross-Sensitivity Data (Correction factor to ETO):
| Gas | Correction Factor |
|---|---|
| Ethylene Oxide | 1.0 |
| Carbon Monoxide | 2.5 |
| Ethanol | 2.5 |
| Methanol | 0.5 |
| Isopropanol | 5.0 |
| i-Butylene | 2.5 |
| Butadiene | 0.9 |
| Ethylene | 0.8 |
| Propane | 1.7 |
| Vinyl Chloride | 1.4 |
| Vinyl Acetate | 2.5 |
| Formic Acid | 5.0 |
Important Notes:
- Performance specifications are based upon environment conditions of +20C, 50% RH, and 1 atm (1013mBar).
- PCB sockets are recommended for sensor pin connection; soldering is to be avoided and will invalidate the warranty.
- Avoid exposure to high concentrations of solvent during storage, fitting, and operation. Use degreasing agents prior to fitting sensors on PCBs.
- Electrochemical gas sensors may fail to meet specifications without warning. For life safety applications, check sensor response to gas before use.
2411261432_Amphenol-EC4-500-ETO_C3659302.pdf