Online Service

Online Service

Contact Person
+86 136 6733 2386
quality Compact MEMS sensor Amphenol MICS-4514 designed for detecting hydrogen ammonia methane and other gases factory
<
quality Compact MEMS sensor Amphenol MICS-4514 designed for detecting hydrogen ammonia methane and other gases factory
quality Compact MEMS sensor Amphenol MICS-4514 designed for detecting hydrogen ammonia methane and other gases factory
>
Specifications
Voltage - Supply:
4.9V~5.1V
Operating Temperature:
-30℃~+85℃
Mfr. Part #:
MICS-4514
Package:
SMD-10P,7x5mm
Key Attributes
Model Number: MICS-4514
Product Description

Product Overview

The MiCS-4514 is a compact MOS sensor featuring two fully independent sensing elements within a single package. Designed as a robust MEMS sensor, it is specifically engineered for the detection of pollution from automobile exhausts. Its key advantages include the smallest footprint for compact designs (5 x 7 x 1.55 mm), suitability for harsh environments, and high-volume manufacturing for cost-effective applications with short lead-times. The sensor is capable of detecting Carbon monoxide (CO), Nitrogen dioxide (NO2), Ethanol (C2H5OH), Hydrogen (H2), Ammonia (NH3), and Methane (CH4).

Product Attributes

  • Brand: SGX Sensortech
  • Sensor Type: MOS
  • Technology: MEMS
  • Package Type: SMD compatible

Technical Specifications

Characteristic Symbol Typ Min Max Unit Notes
RED sensor
Sensing resistance in air R0 - 100 1500 k Measured under synthetic air at 23 5C and 50 10% RH
Typical CO detection range FS - 1 1000 ppm -
Sensitivity factor (Rs in air / Rs at 60 ppm CO) S60 - 1.2 50 - Test conditions: 23 5C and 50 10% RH. Indicative values only.
OX sensor
Sensing resistance in air R0 - 0.8 20 k Measured under synthetic air at 23 5C and 5% RH
Typical NO2 detection range FS - 0.05 10 ppm -
Sensitivity factor (Rs at 0.25 ppm NO2 / Rs in air) SR - 2 - - Test conditions: 23 5C and 5% RH. Indicative values only.
Heating Power
Heating power (RED/OX) PH 76/43 71/30 81/50 mW -
Heating voltage (RED/OX) VH 2.4/1.7 - - V -
Heating current (RED/OX) IH 32/26 - - mA -
Heating resistance at nominal power (RED/OX) RH 74/66 66/59 82/73 -
Operating Conditions & Ratings
Voltage supply Vsupply - 4.9 5.1 V -
Relative humidity range RH - 5 95 %RH -
Ambient operating temperature Tamb - -30 85 C -
Storage temperature range Tsto - -40 120 C -
Storage humidity range RHsto - 5 95 %RH -
Maximum heater power dissipation PH - - 88 (RED)/50 (OX) mW -
Maximum sensitive layer power dissipation Ps - - 8 mW -
Dimensions
Sensor Footprint - - - 5 x 7 x 1.55 mm -
Cavity Dimensions (Tape & Reel) - - - 5.5 x 7.5 x 2.55 (+/- 0.2) mm -

2411261432_Amphenol-MICS-4514_C3659364.pdf

Request A Quote

Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible

You Can Upload Up To 5 Files And Each File Sized 10M Max