The SGX series of PS1 and PS4 Electrochemical gas sensors utilize a revolutionary 'Solid Polymer Electrolyte' technology based on catalytic reaction. These sensors generate a small current proportional to the target gas concentration, offering a stable, high-quality, and cost-effective manufacturing process. Available in a very small size, they are highly sensitive, do not require power, and exhibit very low cross-sensitivity to other gases. Key applications include TLV monitoring, environmental air monitoring, parking garages, steel industry, oil & petrochemical industry, and leakage detection.
Product Attributes
- Brand: SGX
- Technology: Solid Polymer Electrolyte
- Operating Principle: Amperometric, 3-electrode
- Housing Material: PPO
- Origin: Poland (SGX Europe Sp. z o.o.)
Technical Specifications
| Specification | PS1-CO-100 | PS4-CO-100 |
|---|---|---|
| Sensitivity | 25 10 nA / ppm | 25 10 nA / ppm |
| Measurement Range | 0 100 ppm | 0 100 ppm |
| Zero Current | 100 nA | 100 nA |
| Maximum Overload | 1000 ppm | 1000 ppm |
| Response Time (T50) | < 10s | < 10s |
| Response Time (T90) | < 30s | < 30s |
| Repeatability | < 1% | < 1% |
| Lower Detectable Limit (LDL) | 2 ppm | 2 ppm |
| Linear Range | 100 ppm | 100 ppm |
| Resolution (16Bit ADC) | <0.1ppm | <0.1ppm |
| Operating Humidity Range | 15-95% RH | |
| Pressure Range | 800 to 1200 hPa | |
| Storage Temperature | 0 to 20 | |
| Temperature Range | -40C to +55C | |
| Recommended Load Resistor | 100 | |
| Bias Voltage | 0 mV | |
| Warm Up Time | < 60 s | |
| Long-Term Drift | < 1 %/month | |
| Zero Drift in Clean Air | < 2 ppm | |
| Storage Life | 12 months | |
| Expected Lifetime | > 5 years in air | |
| Warranty | 12 months | |
| Weight | < 0.7g | < 6g |
Features
- Small size
- Fast response time
- Wide temperature range
- Extreme linear response up to high concentration
- No electrolyte leakage
- High sensitivity
- Excellent sensitivity at low temperatures
- Stable zero point
Important Notes
- All performance is based on conditions at 20C, 50% RH and 1 atm, flow rate>150qcm/min, using SGX recommended circuitry.
- Sensor performance is temperature dependant; please contact SGX for temperature performance other than 20C.
- Do not solder to the connector pins as this may damage the sensor and thereby invalidate the warranty.
- Details on recommended connector pins can be found in the Frequently Asked Questions within the Gas Sensor section of the SGX website.
- Exposure to high concentrations of solvent vapours should be avoided during storage, fitting into instruments, and operation.
- When using sensors on printed circuit boards (PCBs), degreasing agents should be used prior to the sensor being fitted.
- For life safety performance requirements, it is recommended that all sensors and instruments using these sensors are checked for response to gas before use.
2411272324_Amphenol-PS4-CO-100_C6629220.pdf
Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible