Online Service

Online Service

Contact Person
+86 136 6733 2386
quality Industrial gas sensor Amphenol SGX-F2-5 with water based electrolyte and lightweight design under 8 grams factory
<
quality Industrial gas sensor Amphenol SGX-F2-5 with water based electrolyte and lightweight design under 8 grams factory
>
Specifications
Operating Temperature:
-20℃~+40℃
Mfr. Part #:
SGX-F2-5
Key Attributes
Model Number: SGX-F2-5
Product Description

Product Overview

The SGX Fluorine sensor SGX-F2-5 is a liquid electrochemical gas sensor designed for accurate measurement of gas concentrations. It utilizes a revolutionary innovation in electrochemical sensing, detecting output signals from electrochemical reactions and measuring gas concentration through signal magnitude. The sensor features three catalytic electrodes, a liquid electrolyte, and gas diffusion holes where gas reaches the working electrode for an electrochemical reaction. This generates a current signal linearly proportional to the gas concentration. Key applications include general industry, environmental monitoring, leak detection, emissions, TLV-monitoring, the semiconductor industry, portable and fixed point applications, and water treatment facilities.

Product Attributes

  • Brand: SGX
  • Model: SGX-F2-5
  • Electrolyte Type: Water based
  • Housing Material: PPO
  • Weight: < 8g
  • Origin: SGX Europe Sp. z o.o.

Technical Specifications

Specification Value
Sensitivity 260 80 nA/ppm
Measurement Range 0 5 ppm
Zero Current 20 nA
Maximum Overload 10 ppm
Response Time (T50) < 20s
Response Time (T90) < 60s
Repeatability 2%
Lower Detectable Limit (LDL) 0.05 ppm
Linear Range 5 ppm
Resolution (16Bit ADC) < 0.01ppm
Operating Humidity Range 15-95% RH
Pressure Range 800 to 1200 hPa
Storage Temperature 0 to 20
Temperature Range -20C to +40C
Operating Principle Amperometric
Recommended Load Resistor 220
Bias Voltage 0 mV
Warm Up Time < 60 s
Long-Term Drift < 1 %/month
Zero Drift in Clean Air < 1 ppm
Storage Life 6 months
Expected Lifetime 24 months
Warranty 12 months

Important Notes

  • All performance is based on conditions at 20C, 50% RH and 1 atm, flow rate>150qcm/min, using SGX recommended circuitry.
  • Sensor performance is temperature dependent; please contact SGX for temperature performance other than 20C.
  • Do not solder to the connector pins as this may damage the sensor and thereby invalidate the warranty.
  • Details on recommended connector pins can be found in the Frequently Asked Questions within the Gas Sensor section of the SGX website.

Cross Sensitivity

Gas Formula Test Concentration Sensor Reading
Ammonia NH3 100ppm 0ppm
Carbon Monoxide CO 100ppm 0ppm
Diborane B2H6 0.6ppm 0.3ppm
Hydrogen H2 1000ppm 0ppm
Hydrogen Chloride HCL 20ppm 3ppm
Hydrogen Fluoride HF 0ppm 0ppm
Hydrogen Sulphide H2S 10ppm 0ppm
Ozone O3 0.25ppm 0.05ppm

Note: 1) The above interference factors may vary due to different sensors and service life, please refer to the actual test results. 2) This table is not complete for all cross gases, other gas please contact with us.