Online Service

Online Service

Contact Person
+86 136 6733 2386
quality Accurate ammonia gas sensor Amphenol SGX-7NH3-100 with 0 to 100 ppm range and repeatable measurements factory
<
quality Accurate ammonia gas sensor Amphenol SGX-7NH3-100 with 0 to 100 ppm range and repeatable measurements factory
>
Specifications
Measurement Range:
800mbar~1200mbar
Operating Temperature:
-40℃~+50℃
Mfr. Part #:
SGX-7NH3-100
Key Attributes
Model Number: SGX-7NH3-100
Product Description

Product Overview

The SGX-7NH3-100 is an industrial ammonia (NH3) sensor designed for reliable gas detection. It offers a measurement range of 0-100 ppm with a T90 response time of less than 90 seconds. This sensor is suitable for applications requiring accurate monitoring of ammonia levels in various industrial environments. It features a linear response, good repeatability, and a long expected operating life of over 24 months in air. The sensor is intrinsically safe, with specific voltage and current ratings.

Product Attributes

  • Brand: SGX Sensortech
  • Product Model: SGX-7NH3-100
  • Type: Industrial Ammonia (NH3) Sensor
  • Compliance: RoHS compliant
  • Warranty Note: Warranty may be invalidated if glued or soldered to connector pins; use PCB sockets.

Technical Specifications

Specification Details
Measurement Range 0 - 100 ppm
T90 Response Time < 90 seconds
Output Signal 115 ± 45 nA / ppm
Typical Baseline Range (pure air) ±1 ppm NH3 equivalent
Linearity Linear
Repeatability ±10%
Maximum Overload 200 ppm
Resolution (Electronics dependent) 1 ppm
Long Term Output Drift < 20% per annum
Expected Operating Life > 24 months in air
Recommended Load Resistor 10 ohms
Temperature Range -40°C to +50°C
Pressure Range 800 to 1200 mbar
Operating Humidity Range 15% to 90% RH
Recommended Storage Temp 0°C to 20°C
Intrinsic Safety: Max o/c Voltage 1.3 V
Intrinsic Safety: Max s/c Current <1.0 A
Intrinsic Safety: Max at 2000ppm 0.3 mA
Cross Sensitivity: Carbon Monoxide (500ppm) 0 ppm
Cross Sensitivity: Hydrogen Sulphide (15ppm) <30 ppm
Cross Sensitivity: Sulphur Dioxide (20ppm) -6 ppm
Cross Sensitivity: Nitric Oxide (35ppm) 0 ppm
Cross Sensitivity: Nitrogen Dioxide (20ppm) -25 ppm
Cross Sensitivity: Hydrogen (100ppm) 0 ppm

Note: All performance specifications are based upon environmental conditions of 20°C, 50% relative humidity, 101kPa. Cross sensitivity data is for information only and may fluctuate.


2411261432_Amphenol-SGX-7NH3-100_C3659377.pdf

Request A Quote

Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible

You Can Upload Up To 5 Files And Each File Sized 10M Max