Online Service

Online Service

Contact Person
+86 136 6733 2386
quality Electrochemical Sensor Amphenol PS1-O2-25% for Precise Oxygen Measurement in Industrial Environments factory
<
quality Electrochemical Sensor Amphenol PS1-O2-25% for Precise Oxygen Measurement in Industrial Environments factory
>
Specifications
Mfr. Part #:
PS1-O2-25%
Key Attributes
Model Number: PS1-O2-25%
Product Description

Product Overview

The SGX series of PS1 and PS4 Electrochemical gas sensors utilize a revolutionary Solid Polymer Electrolyte technology based on catalytic reaction principles. These sensors generate a small current proportional to the target gas concentration, offering a stable, high-quality, and cost-effective manufacturing process. They are characterized by their very small size, high sensitivity, low power consumption, and minimal cross-sensitivity to other gases. Ideal for applications in Medical, Industrial, Combustion Control, Food Industry, and General Gas Detection.

Product Attributes

  • Brand: SGX
  • Technology: Solid Polymer Electrolyte
  • Housing Material: PPO
  • Lead Free: Yes
  • Power Consumption: Low
  • Sensor Type: Capillary

Technical Specifications

Specification PS1-O2-25% PS4-O2-25%
Sensitivity (nA/ppm) 0.2 0.03 0.2 0.03
Measurement Range (%vol) 0 25 0 25
Zero Current (A) 40-60 40-60
Maximum Overload (%vol) 30 30
Response Time (T50) < 5s < 5s
Response Time (T90) < 10s < 10s
Lower Detectable Limit (LDL) (%vol) 0.5 0.5
Resolution (16Bit ADC) (%vol) 0.01 0.01
Operating Humidity Range (%) 15-95% RH
Pressure Range (hPa) 800 to 1200
Storage Temperature () 0 to 20
Temperature Range () -20C to +55C
Operating Principle Amperometric, 3-electrode
Recommended Load Resistor () 220
Bias Voltage (mV) -400 to -600
Warm Up Time (min) < 15
Long-Term Drift (%/month) < 1
Zero Drift in Clean Air (%vol) < 0.2
Storage Life (months) 12
Expected Lifetime (years) > 5
Warranty (months) 12
Weight (g) < 0.7 < 6

Important Notes

  • All performance is based on conditions at 20C, 50% RH and 1 atm, flow rate>150qcm/min, using SGX recommended circuitry.
  • Sensor performance is temperature dependent; please contact SGX for temperature performance other than 20C.
  • Do not solder to the connector pins as this may damage the sensor and thereby invalidate the warranty.
  • Details on recommended connector pins can be found in the Frequently Asked Questions within the Gas Sensor section of the SGX website.
  • Handling Precaution: Do not solder the sensor directly onto a PCB or to wires, excessive heat could cause damage. Use PCB sockets and firmly push-fit the sensor into the application, so that a correct electrical connection is achieved.
  • Where life safety is a performance requirement, it is recommended that all sensors and instruments using these sensors are checked for response to gas before use.

Cross Sensitivity

Note: 1) The above interference factors may vary due to different sensors and service life, please refer to the actual test results. 2) This table is not complete for all cross gases, other gas please contact with us.

Gas Formula Test Concentration Sensor Reading
Ammonia NH3 20ppm 0ppm
Carbon Dioxide CO2 5000ppm 0ppm
Carbon Monoxide CO 1%vol 0ppm
Chlorine CL2 / HCN 50ppm 1ppm
Hydrocarbons (unsaturated) H2 100ppm 0ppm
Hydrogen Cyanide C3H8O 1000ppm 0ppm
Hydrogen NO 25ppm 10ppm
Isopropanol NO2 0.5ppm 0ppm
Nitric Oxide O3 20ppm 0ppm
Nitrogen Dioxide SO2 0ppm 0ppm
Ozone
Sulphur Dioxide

2411261442_Amphenol-PS1-O2-25-_C5711028.pdf

Request A Quote

Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible

You Can Upload Up To 5 Files And Each File Sized 10M Max