SGX Solid Polymer Electrolyte Gas Sensors - VOC
Product Overview
The SGX series of PS1 and PS4 Electrochemical gas sensors leverage a revolutionary 'Solid Polymer Electrolyte' technology based on catalytic reaction principles. These sensors generate a small current proportional to the target gas concentration, offering a stable, high-quality, and cost-effective manufacturing process. They are characterized by their very small size, high sensitivity, zero power consumption, and low cross-sensitivity to other gases. Ideal for general gas detection, consumer markets, VOC gas detection, mobile phone noses, and indoor/outdoor air quality monitoring, these sensors provide reliable performance in various applications.
Product Attributes
- Brand: SGX
- Technology: Solid Polymer Electrolyte
- Operating Principle: Amperometric, 3-electrode
- Housing Material: PPO
- Origin: SGX Europe Sp. z o.o.
- Warranty: 12 months
- Storage Life: 12 months
- Expected Lifetime: > 3 years in air
Technical Specifications
| Model | PS1-VOC-10 | PS4-VOC-10 | Specification | Value |
|---|---|---|---|---|
| Weight | < 0.7g | < 6g | ||
| Sensitivity | 55 15 nA / ppm | |||
| Measurement Range | 0 10ppm | |||
| Zero Current | 100 nA | |||
| Maximum Overload | 100 ppm | |||
| Response Time | T50 < 10s, T90 < 30s | |||
| Repeatability | 1% | |||
| Lower Detectable Limit (LDL) | < 1 ppm | |||
| Linear Range | 10 ppm | |||
| Resolution (16Bit ADC) | 0.01ppm | |||
| Operating Humidity Range | 15-95% RH | |||
| Pressure Range | 800 to 1200 hPA | |||
| Storage Temperature | 0 to 20 | |||
| Temperature Range | -40C to +55C | |||
| Recommended Load Resistor | 100 | |||
| Bias Voltage | 0 mV | |||
| Warm Up Time | < 60 s | |||
| Long-Term Drift | < 1 %/month | |||
| Zero Drift in Clean Air | < 2 ppm | |||
| Storage Conditions | 0-20 C |
Key Applications
- General Gas Detection
- Consumer Market
- VOC Gas Detection
- Mobile Phone Nose
- Indoor & Outdoor Air Quality
- Low Power Nose
Features
- Small size
- High sensitivity
- Wide temperature range
- Fast response time
- No electrolyte leakage
- Low cost at large volumes
- Individually calibrated (including test report)
Important Notes
- All performance is based on conditions at 20C, 50% RH and 1 atm, flow rate>150qcm/min, using SGX recommended circuitry.
- Sensor performance is temperature dependant; please contact SGX for temperature performance other than 20C.
- Do not solder to the connector pins as this may damage the sensor and thereby invalidate the warranty.
- Details on recommended connector pins can be found in the Frequently Asked Questions within the Gas Sensor section of the SGX website.
Cross Sensitivity
| Gas | Formula | Test Concentration | Sensor Reading |
|---|---|---|---|
| Acetaldehyde | C2H4O | 5ppm | 3.84ppm |
| Dimethyl Disulfide | C2H6S2 | 2ppm | 6.79ppm |
| Hydrogen Chloride | HCL | 5ppm | 0.27ppm |
| Acetic Acid | CH3COOH | 5ppm | 1.1ppm |
| Unsaturated hydrocarbons | C2H2 | 5ppm | 4.65ppm |
| Hydrogen Cyanide | HCN | 3.84ppm | 0.36ppm |
| Acetylene | C2H2 | 6.79ppm | 1.64ppm |
| Ethanol | C2H6O | 0.27ppm | 1.83ppm |
| Isobutene | C4H8 | 5ppm | 5ppm |
| Acrylonitrile | C3H3N | 5ppm | 0.4ppm |
| Ethyl Mercaptan | C2H6S | 5ppm | 8.97ppm |
| Methanol | CH4O | 5ppm | 5.96ppm |
| Ammonia | NH3 | 5ppm | 1.5ppm |
| Ethylene | C2H4 | 5ppm | 0.59ppm |
| Methyl Mercaptan | C2H6S | 5ppm | 7ppm |
| Benzene | C6H6 | 5ppm | 1.1ppm |
| Formaldehyde | HCHO | 5ppm | 5.29ppm |
| P-xylene | C8H10 | 5ppm | 0.59ppm |
| Trimethylamine | C3H9N | 5ppm | 0.65ppm |
| Butadiene | C4H6 | 5ppm | 8.68ppm |
| Formic Acid | HCOOH | 5ppm | 5.37ppm |
| Styrene | C8H8 | 0.5ppm | 7.5ppm |
| Carbon Disulfide | CS2 | 5ppm | 1.23ppm |
| Gasoline Volatilization | (Dimensionless) | 5ppm | 5.5ppm |
| Sulphur Dioxide | SO2 | 5ppm | 5ppm |
| Carbon Monoxide | CO | 5ppm | 3.38ppm |
| Hydrogen | H2 | 5ppm | 1.15ppm |
| Toluene | C7H8 | 5ppm | 0.81ppm |
Note: 1) The above interference factors may vary due to different sensors and service life, please refer to the actual test results. 2) This table is not complete for all cross gases, other gas please contact with us.