Specifications
Measurement Range:
1.2bar~800mbar
Operating Temperature:
-20℃~+55℃
Mfr. Part #:
SGX-HF-10
Key Attributes
Model Number: SGX-HF-10
Product Description

Product Overview

The SGX-HF-10 is a high-sensitivity amperometric gas sensor designed for accurate gas measurement in various applications. It features a small size, wide temperature range, low cross-sensitivity, and high selectivity, making it suitable for environmental air monitoring, leak detection, power transformer failure analysis, emissions monitoring, and TLV-monitoring. The sensor offers excellent sensitivity, particularly at low temperatures, and boasts a double-sealed housing for advanced leakage protection. Its performance is optimized with recommended circuitry and a specific load resistor.

Product Attributes

  • Brand: SGX
  • Model: SGX-HF-10
  • Housing Material: PPO
  • Origin: SGX Europe Sp. z o.o.
  • Warranty: 12 months

Technical Specifications

Specification Value
Sensitivity 350 100 nA/ppm
Measurement Range 0 10 ppm
Zero Current 100 nA
Maximum Overload 20 ppm
Response Time (T50) < 40s
Response Time (T90) < 80s
Repeatability < 2%
Lower Detectable Limit (LDL) 0.4 ppm
Linear Range 10 ppm
Resolution (16Bit ADC) <0.1ppm
Operating Humidity Range 15-95% RH
Pressure Range 800 to 1200 hPA
Storage Temperature 0 to 20
Temperature Range -20C to +55C
Operating Principle Amperometric
Recommended Load Resistor 220
Bias Voltage 0 mV
Warm Up Time < 60 s
Long-Term Drift < 1 %/month
Zero Drift in Clean Air < 1 ppm
Storage Life 6 months
Expected Lifetime 24 months
Weight < 6g

Cross Sensitivity

Gas Formula Test Concentration Sensor Reading
Arsine NH3 0.5ppm 13ppm
Carbon Monoxide CO 100ppm 0.7ppm
Chlorine CL2 1ppm 0ppm
Hydrogen H2 100ppm 0ppm
Hydrogen Sulphide H2S 0.7ppm 0ppm
Nitric Oxide NO 50ppm 0ppm
Fluorine F2 10ppm 0ppm
Silane SiH4 10ppm 0ppm

Note: 1) The above interference factors may vary due to different sensors and service life, please refer to the actual test results. 2) This table is not complete for all cross gases, other gas please contact with us.

Temperature Curve

Visual representation of temperature dependence. Specific data points are provided in the original document.