SGX Solid Polymer Electrolyte Gas Sensors - Ozone (PS1-O3-5 & PS4-O3-5)
The SGX series of PS1 and PS4 Electrochemical gas sensors leverage a revolutionary 'Solid Polymer Electrolyte' technology based on catalytic reaction principles. These sensors generate a small current proportional to the target gas concentration, offering a stable, high-quality, and cost-effective manufacturing process. Designed for high sensitivity and low power consumption, they exhibit minimal cross-sensitivity to other gases and are available in a compact size. The PS1-O3-5 and PS4-O3-5 models are specifically designed for ozone detection.
Key Applications:
- Swimming Pools
- Chemical Industry
- Portable and Fixed Point Applications
- Environmental Monitoring
- Semiconductor Industry
- Water Treatment
- Leak Detection
- TLV-Monitoring
Product Attributes:
- Brand: SGX
- Technology: Solid Polymer Electrolyte
- Housing Material: PPO
- Origin: SGX Europe Sp. z o.o.
Technical Specifications:
| Specification | PS1-O3-5 | PS4-O3-5 |
|---|---|---|
| Sensitivity | 60 ±20 nA / ppm | |
| Measurement Range | 0 5 ppm | |
| Zero Current | ± 20 nA | |
| Maximum Overload | 10 ppm | |
| Response Time | T50 < 20s, T90 < 60s | |
| Repeatability | < 2% | |
| Lower Detectable Limit (LDL) | 0.05 ppm | |
| Linear Range | 5 ppm | |
| Resolution (16Bit ADC) | <0.01ppm | |
| Operating Humidity Range | 15-95% RH | |
| Pressure Range | 800 to 1200 hPA | |
| Storage Temperature | 0 to 20 | |
| Temperature Range | -20°C to +40°C | |
| Operating Principle | Amperometric, 3-electrode | |
| Recommended Load Resistor | 220 Ω | |
| Bias Voltage | 0 mV | |
| Warm Up Time | < 60 s | |
| Long-Term Drift | < 1 %/month | |
| Zero Drift in Clean Air | < 1 ppm | |
| Storage Life | 12 months | |
| Expected Lifetime | 24 months | |
| Warranty | 12 months | |
| Weight | < 0.7g | < 6g |
Features:
- Small size
- Wide temperature range
- Low cross sensitivity
- No electrolyte leakage
- High sensitivity
- Excellent sensitivity at low temperatures
- Stable zero point
Cross Sensitivity:
| Gas | Formula | Test Concentration | Sensor Reading |
|---|---|---|---|
| Ammonia | NH3 | 50ppm | 0ppm |
| Carbon Monoxide | CO | 1000ppm | 0ppm |
| Methane | CH4 | 300ppm | 0ppm |
| Hydrogen | H2 | 1%vol | 0ppm |
| Hydrogen Cyanide | HCN | 3000ppm | 10ppm |
| Isopropanol | C3H8O | 1000ppm | n.e |
| Nitric Oxide | NO | 35ppm | 0ppm |
| Sulphur Dioxide | SO2 | 5ppm | 1ppm |
Note: Interference factors may vary. Refer to actual test results. Table may not be exhaustive; contact SGX for other gases.
Dimensions:
PS1-O3-5: (Diagram not provided in source text)
PS4-O3-5: (Diagram not provided in source text)
Important Notes:
- Performance is based on conditions at 20°C, 50% RH and 1 atm, flow rate >150qcm/min, using SGX recommended circuitry.
- Sensor performance is temperature dependent; contact SGX for performance outside 20°C.
- Do not solder to connector pins to avoid damage and warranty invalidation.
- Recommended connector pin details are available in the SGX website's FAQ section.
- Avoid exposure to high concentrations of solvent vapors during storage, fitting, and operation.
- When using sensors on PCBs, use degreasing agents prior to fitting.
- For life safety applications, check sensor response to gas before use.
2411011328_Amphenol-PS4-O3-5_C6953630.pdf
Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible