Product Overview
The SGX Solid Polymer Electrolyte Gas Sensors, specifically the PS1 and PS4 series, utilize a revolutionary Solid Polymer Electrolyte technology based on catalytic reaction principles. These sensors generate a small current proportional to the target gas concentration, offering a stable, high-quality, and cost-effective manufacturing process. They are characterized by their very small size, high sensitivity, zero power consumption, and low cross-sensitivity to other gases. Key applications include TLV monitoring, the oil & petrochemical industry, leak detection, the steel industry, and parking garages.
Product Attributes
- Brand: SGX
- Technology: Solid Polymer Electrolyte
- Housing Material: PPO
Technical Specifications
| Model | Specification | Value |
|---|---|---|
| PS1-CO-1000 / PS4-CO-1000 | Sensor Type | Carbon Monoxide |
| Sensitivity | 25 10 nA / ppm | |
| Measurement Range | 0 1000 ppm | |
| Zero Current | 100 nA | |
| Maximum Overload | 2000 ppm | |
| Response Time (T90) | < 30s | |
| Repeatability | < 1% | |
| Lower Detectable Limit (LDL) | 2 ppm | |
| Linear Range | 1000 ppm | |
| Resolution (16Bit ADC) | 0.1ppm | |
| Environmental Details | Operating Humidity Range | 15-95% RH |
| Pressure Range | 800 to 1200 hPa | |
| Storage Temperature | 0 to 20 | |
| Temperature Range | -40C to +55C | |
| Operating Principle | Amperometric, 3-electrode | |
| Recommended Load Resistor | 100 | |
| Lifetime Details | Warm Up Time | < 60 s |
| Long-Term Drift | < 1 %/month | |
| Zero Drift in Clean Air | < 2 ppm | |
| Storage Life | 12 months | |
| Expected Lifetime | > 5 years in air | |
| Weight | PS1-CO-1000 | < 0.7g |
| PS4-CO-1000 | < 6g | |
| Warranty | Standard Warranty | 12 months |
| Storage Conditions | 0-20C |
Features
- Small size
- Wide temperature range
- Low cross sensitivity
- No electrolyte leakage
- High sensitivity
- Fast response time
- Extreme linear response up to high concentration
Important Notes
- All performance is based on conditions at 20C, 50% RH and 1 atm, flow rate >150 qcm/min, using SGX recommended circuitry.
- Sensor performance is temperature dependent; please contact SGX for temperature performance other than 20C.
- Do not solder to the connector pins as this may damage the sensor and thereby invalidate the warranty.
- Details on recommended connector pins can be found in the Frequently Asked Questions within the Gas Sensor section of the SGX website.
- Exposure to high concentrations of solvent vapours should be avoided during storage, fitting into instruments, and operation.
- When using sensors on printed circuit boards (PCBs), degreasing agents should be used prior to the sensor being fitted.
- For life safety performance requirements, it is recommended that all sensors and instruments using these sensors are checked for response to gas before use.
Cross Sensitivity
| Gas | Formula | Test Concentration | Sensor Reading |
|---|---|---|---|
| Alcohols | R-OH | 1000ppm | 0ppm |
| Ammonia | NH3 | 50ppm | 0ppm |
| Carbon Dioxide | CO2 | 1000ppm | 1ppm |
| Chlorine | CL2 | 0ppm | 0ppm |
| Ethylene | C2H4 | 10ppm | 0ppm |
| Hydrogen Cyanide | HCN | 50ppm | 0ppm |
| Hydrogen | H2 | 100ppm | 20ppm |
| Hydrogen Sulphide | H2S | 50ppm | 0ppm |
| Isopropanol | C3H7OH | 1000ppm | 0ppm |
| Methanal | CH4 | 1%vol | 0ppm |
| Nitric Oxide | NO | 25ppm | 10ppm |
| Nitrogen Dioxide | NO2 | 10ppm | 0ppm |
| Sulphur Dioxide | SO2 | 10ppm | 0ppm |
Note: Interference factors may vary due to different sensors and service life. This table is not exhaustive for all cross gases; contact SGX for further information.
2411272324_Amphenol-PS1-CO-1000_C6629192.pdf