Online Service

Online Service

Contact Person
+86 136 6733 2386
quality Carbon Monoxide Detection Sensor Amphenol PS1-CO-1000 Featuring Solid Polymer Electrolyte Technology factory
<
quality Carbon Monoxide Detection Sensor Amphenol PS1-CO-1000 Featuring Solid Polymer Electrolyte Technology factory
>
Specifications
Measurement Range:
1.2bar~800mbar
Operating Temperature:
-40℃~+55℃
Mfr. Part #:
PS1-CO-1000
Key Attributes
Model Number: PS1-CO-1000
Product Description

Product Overview

The SGX Solid Polymer Electrolyte Gas Sensors, specifically the PS1 and PS4 series, utilize a revolutionary Solid Polymer Electrolyte technology based on catalytic reaction principles. These sensors generate a small current proportional to the target gas concentration, offering a stable, high-quality, and cost-effective manufacturing process. They are characterized by their very small size, high sensitivity, zero power consumption, and low cross-sensitivity to other gases. Key applications include TLV monitoring, the oil & petrochemical industry, leak detection, the steel industry, and parking garages.

Product Attributes

  • Brand: SGX
  • Technology: Solid Polymer Electrolyte
  • Housing Material: PPO

Technical Specifications

Model Specification Value
PS1-CO-1000 / PS4-CO-1000 Sensor Type Carbon Monoxide
Sensitivity 25 10 nA / ppm
Measurement Range 0 1000 ppm
Zero Current 100 nA
Maximum Overload 2000 ppm
Response Time (T90) < 30s
Repeatability < 1%
Lower Detectable Limit (LDL) 2 ppm
Linear Range 1000 ppm
Resolution (16Bit ADC) 0.1ppm
Environmental Details Operating Humidity Range 15-95% RH
Pressure Range 800 to 1200 hPa
Storage Temperature 0 to 20
Temperature Range -40C to +55C
Operating Principle Amperometric, 3-electrode
Recommended Load Resistor 100
Lifetime Details Warm Up Time < 60 s
Long-Term Drift < 1 %/month
Zero Drift in Clean Air < 2 ppm
Storage Life 12 months
Expected Lifetime > 5 years in air
Weight PS1-CO-1000 < 0.7g
PS4-CO-1000 < 6g
Warranty Standard Warranty 12 months
Storage Conditions 0-20C

Features

  • Small size
  • Wide temperature range
  • Low cross sensitivity
  • No electrolyte leakage
  • High sensitivity
  • Fast response time
  • Extreme linear response up to high concentration

Important Notes

  • All performance is based on conditions at 20C, 50% RH and 1 atm, flow rate >150 qcm/min, using SGX recommended circuitry.
  • Sensor performance is temperature dependent; please contact SGX for temperature performance other than 20C.
  • Do not solder to the connector pins as this may damage the sensor and thereby invalidate the warranty.
  • Details on recommended connector pins can be found in the Frequently Asked Questions within the Gas Sensor section of the SGX website.
  • Exposure to high concentrations of solvent vapours should be avoided during storage, fitting into instruments, and operation.
  • When using sensors on printed circuit boards (PCBs), degreasing agents should be used prior to the sensor being fitted.
  • For life safety performance requirements, it is recommended that all sensors and instruments using these sensors are checked for response to gas before use.

Cross Sensitivity

Gas Formula Test Concentration Sensor Reading
Alcohols R-OH 1000ppm 0ppm
Ammonia NH3 50ppm 0ppm
Carbon Dioxide CO2 1000ppm 1ppm
Chlorine CL2 0ppm 0ppm
Ethylene C2H4 10ppm 0ppm
Hydrogen Cyanide HCN 50ppm 0ppm
Hydrogen H2 100ppm 20ppm
Hydrogen Sulphide H2S 50ppm 0ppm
Isopropanol C3H7OH 1000ppm 0ppm
Methanal CH4 1%vol 0ppm
Nitric Oxide NO 25ppm 10ppm
Nitrogen Dioxide NO2 10ppm 0ppm
Sulphur Dioxide SO2 10ppm 0ppm

Note: Interference factors may vary due to different sensors and service life. This table is not exhaustive for all cross gases; contact SGX for further information.


2411272324_Amphenol-PS1-CO-1000_C6629192.pdf

Request A Quote

Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible

You Can Upload Up To 5 Files And Each File Sized 10M Max