Product Overview
The SGX-HCL-30 is a Hydrogen Chloride (HCl) sensor utilizing SGX's innovative liquid electrochemical sensing technology. This sensor accurately measures HCl gas concentration by detecting output signals from electrochemical reactions. It features a revolutionary innovation in electrochemical sensing, providing high sensitivity and selectivity. Key applications include general industry, environmental monitoring, leak detection, emissions monitoring, TLV-monitoring, the semiconductor industry, and industrial safety. The sensor is designed for reliable performance in various environmental conditions.
Product Attributes
- Brand: SGX
- Technology: Liquid Electrochemical Gas Sensors
- Electrolyte: Water based
- Housing Material: PPO
- Housing: Double sealed for advanced leakage protection
Technical Specifications
| Specification | Value | Unit |
|---|---|---|
| Model | SGX-HCL-30 | - |
| Measurement Range | 0 30 | ppm |
| Sensitivity | 330 100 | nA/ppm |
| Zero Current | 100 | nA |
| Maximum Overload | 100 | ppm |
| Response Time (T50) | < 40 | s |
| Response Time (T90) | < 80 | s |
| Repeatability | 2 | % |
| Lower Detectable Limit (LDL) | 0.3 | ppm |
| Resolution (16Bit ADC) | <0.1 | ppm |
| Operating Humidity Range | 15-95 | % RH (non-condensing) |
| Pressure Range | 800 to 1200 | hPa |
| Storage Temperature | 0 to 20 | |
| Temperature Range | -40 to +55 | C |
| Long-Term Drift | < 1 | %/month |
| Zero Drift in Clean Air | < 1 | ppm |
| Storage Life | 6 | months |
| Expected Lifetime | 24 | months |
| Warranty | 12 | months |
| Operating Principle | Amperometric | - |
| Recommended Load Resistor | 220 | |
| Bias Voltage | 0 | mV |
| Warm Up Time | < 60 | s |
| Weight | < 6 | g |
2504101957_Amphenol-SGX-HCL-30_C7080120.pdf
Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible