Specifications
Measurement Range:
1.2bar~800mbar
Operating Temperature:
-20℃~+55℃
Mfr. Part #:
PS4-HCHO-5
Key Attributes
Model Number: PS4-HCHO-5
Product Description

Product Overview

The SGX series of PS1 and PS4 Formaldehyde sensors leverage a revolutionary 'Solid Polymer Electrolyte' technology based on catalytic reaction principles. These sensors generate a small current proportional to the formaldehyde concentration, offering a stable, high-quality, and cost-effective manufacturing process. Key advantages include a very small size, high sensitivity, no power consumption, and very low cross-sensitivity from other gases. They are ideal for TLV Monitoring and Indoor Air Quality applications.

Product Attributes

  • Brand: SGX
  • Technology: Solid Polymer Electrolyte
  • Housing Material: PPO
  • Origin: Poland (SGX Europe Sp. z o.o.)

Technical Specifications

Specification Model: PS1-HCHO-5 Model: PS4-HCHO-5
Sensitivity 35 ± 20 nA / ppm 35 ± 20 nA / ppm
Measurement Range 0 5 ppm 0 5 ppm
Zero Current ± 2 nA ± 2 nA
Maximum Overload 100 ppm 100 ppm
Response Time (T50) < 20s < 20s
Response Time (T90) < 120s < 120s
Repeatability 1% 1%
Lower Detectable Limit (LDL) ≤0.05 ppm ≤0.05 ppm
Linear Range 5 ppm 5 ppm
Resolution (16Bit ADC) 0.01ppm 0.01ppm
Operating Humidity Range 15-95% RH 15-95% RH
Pressure Range 800 to 1200 hPa 800 to 1200 hPa
Storage Temperature 0 to 20°C 0 to 20°C
Temperature Range -20°C to +55°C -20°C to +55°C
Operating Principle Amperometric, 3-electrode Amperometric, 3-electrode
Recommended Load Resistor 100 Ω 100 Ω
Bias Voltage 0 mV 0 mV
Warm Up Time < 60 s < 60 s
Long-Term Drift < 1 %/month < 1 %/month
Zero Drift in Clean Air < 0.2 ppm < 0.2 ppm
Storage Life 12 months 12 months
Expected Lifetime > 3 years in air > 3 years in air
Storage Conditions 0-20°C 0-20°C
Warranty 12 months 12 months
Weight < 0.7g < 6g

Important Notes

  • All performance is based on conditions at 20°C, 50% RH and 1 atm, flow rate>150qcm/min, using SGX recommended circuitry.
  • Sensor performance is temperature dependent; please contact SGX for temperature performance other than 20°C.
  • Do not solder to the connector pins as this may damage the sensor and thereby invalidate the warranty.
  • Details on recommended connector pins can be found in the Frequently Asked Questions within the Gas Sensor section of the SGX website.
  • Exposure to high concentrations of solvent vapours should be avoided during storage, fitting into instruments, and operation.
  • When using sensors on printed circuit boards (PCBs), degreasing agents should be used prior to the sensor being fitted.
  • For life safety performance requirements, it is recommended that all sensors and instruments using these sensors are checked for response to gas before use.

Cross Sensitivity

Gas Formula Test Concentration Sensor Reading (PS1/PS4)
Ammonia NH3 100ppm 0ppm
Benzene C6H6 50ppm 0ppm
Carbon Dioxide CO2 5000ppm 0ppm
Chlorine CL2 20ppm 0ppm
Ethanol C2H6O 100ppm 0ppm
Ethylene C2H4 100ppm 0ppm
Hydrogen Chloride HCL 5ppm 0ppm
Hydrogen Cyanide HCN 20ppm < 1ppm
Hydrogen H2 100ppm < 3ppm
Hydrogen H2 20 000ppm < 50ppm
Methane CH4 10 000ppm 0ppm
Nitrogen Dioxide NO2 10ppm 0ppm
Sulphur Dioxide SO2 10ppm < 1ppm
Toluene C7H8 50ppm 0ppm

Note: 1) The above interference factors may vary due to different sensors and service life, please refer to the actual test results. 2) This table is not complete for all cross gases, for other gases please contact us.


2404231446_Amphenol-PS4-HCHO-5_C7030159.pdf

Request A Quote

Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible

You Can Upload Up To 5 Files And Each File Sized 10M Max