working temperature:
-40℃~+125℃
Current Range:
10A
Voltage - Supply:
3V~3.6V
Current Terminal Resistance:
0.85mΩ
Response Time (tr):
4us
Sensitivity:
132mV/A
Bidirectional Current Detection:
Support
Mfr. Part #:
ACS722KMATR-10AB-T
Package:
SOIC-16
Key Attributes
Model Number: ACS722KMATR-10AB-T
Product Description

Product Overview

The Allegro ACS722 is a highly accurate, Hall-effect-based current sensor IC designed for AC or DC current sensing in industrial, commercial, and communication systems. Its economical and precise solution features a low-offset, linear Hall sensor circuit with a low-resistance copper conduction path (0.85 m typical) for minimal power loss. The device's small SOIC16 package is ideal for space-constrained applications, offering significant cost savings. Key benefits include patented digital temperature compensation for excellent accuracy over temperature, industry-leading noise performance with improved bandwidth, and high isolation capabilities, eliminating the need for costly isolation techniques. Typical applications include motor control, load detection and management, switched-mode power supplies, and overcurrent fault protection.

Product Attributes

  • Brand: Allegro
  • Certifications: UL60950-1 (ed. 2) certified, TV America Certificate Number: U8V 16 03 54214 040, CB Certificate Number: US-32210-M1-UL, CB 16 03 54214 039
  • Package: SOIC16 (MA)
  • Material: Leadframe plated with 100% matte tin. Internally Pb-free (except for flip-chip high-temperature Pb-based solder balls).

Technical Specifications

Characteristic Symbol Test Conditions Value Units
General Specifications
Primary Conductor Resistance RIP TA = 25C 0.85 m
Supply Voltage VCC 3 to 3.6 V
Supply Current ICC VCC within VCC(min) and VCC(max) 9 mA
Internal Bandwidth (BW_SEL tied to GND) BWi Small signal 3 dB; CL = 1 nF 80 kHz
Internal Bandwidth (BW_SEL tied to VCC) BWi Small signal 3 dB; CL = 1nF 20 kHz
Input referenced noise (BW_i = 80 kHz) IN TA = 25C, CL = 1 nF 84 mA(rms)
Input referenced noise (BW_i = 20 kHz) IN TA = 25C, CL = 1 nF 42 mA(rms)
Nonlinearity ELIN Through full range of IP 1 %
Power-On Time tPO TA = 25C, IP = IPR(max) applied 64 s
Selection Guide Models
Part Number IPR (A) Sens(Typ) at VCC = 3.3 V (mV/A) TA (C) Packing
ACS722KMATR-10AB-T 10 132 40 to 125 Tape and Reel, 3000 pieces per reel
ACS722KMATR-20AB-T 20 66 40 to 125 Tape and Reel, 3000 pieces per reel
ACS722KMATR-40AB-T 40 33 40 to 125 Tape and Reel, 3000 pieces per reel
Accuracy Performance (ACS722KMATR-10AB-T)
Current Sensing Range IPR 10 A
Sensitivity Sens IPR(min) < IP < IPR(max) 132 mV/A
Total Output Error ETOT IP = IPR(max), TA = 25C to 125C 1.7 %
Total Output Error ETOT IP = IPR(max), TA = 40C to 25C 2.5 %
Sensitivity Error ESENS TA = 25C to 125C; measured at IP = IPR(max) 1.5 %
Sensitivity Error ESENS TA = 40C to 25C; measured at IP = IPR(max) 2.3 %
Offset Voltage VOE IP = 0 A; TA = 25C to 125C 7 mV
Offset Voltage VOE IP = 0 A; TA = -40C to 25C 20 mV
Accuracy Performance (ACS722KMATR-20AB-T)
Current Sensing Range IPR 20 A
Sensitivity Sens IPR(min) < IP < IPR(max) 66 mV/A
Total Output Error ETOT IP = IPR(max), TA = 25C to 125C 1.2 %
Total Output Error ETOT IP = IPR(max), TA = 40C to 25C 2.1 %
Sensitivity Error ESENS TA = 25C to 125C; measured at IP = IPR(max) 0.75 %
Sensitivity Error ESENS TA = 40C to 25C; measured at IP = IPR(max) 1.25 %
Offset Voltage VOE IP = 0 A; TA = 25C to 125C 4.5 mV
Offset Voltage VOE IP = 0 A; TA = -40C to 25C 10 mV
Accuracy Performance (ACS722KMATR-40AB-T)
Current Sensing Range IPR 40 A
Sensitivity Sens IPR(min) < IP < IPR(max) 33 mV/A
Total Output Error ETOT IP = IPR(max), TA = 25C to 125C 1.25 %
Total Output Error ETOT IP = IPR(max), TA = 40C to 25C 2 %
Sensitivity Error ESENS TA = 25C to 125C; measured at IP = IPR(max) 1.2 %
Sensitivity Error ESENS TA = 40C to 25C; measured at IP = IPR(max) 1.75 %
Offset Voltage VOE IP = 0 A; TA = 25C to 125C 3 mV
Offset Voltage VOE IP = 0 A; TA = -40C to 25C 5 mV
Isolation Characteristics
Dielectric Strength Test Voltage VISO Agency type-tested for 60 seconds per UL 60950-1 (edition. 2). Production tested at 3000 VRMS for 1 second, in accordance with UL 60950-1 (edition. 2). 4800 VRMS
Working Voltage for Basic Isolation VWVBI According to UL 60950-1 (edition 2) 1097 VRMS or VDC
Working Voltage for Reinforced Isolation VWVRI According to UL 60950-1 (edition 2) 565 VRMS or VDC
Clearance Dcl Minimum distance through air from IP leads to signal leads. 7.5 mm
Creepage Dcr Minimum distance along package body from IP leads to signal leads 8.2 mm
Absolute Maximum Ratings
Supply Voltage VCC 6 V
Maximum Continuous Current ICMAX TA = 25C 60 A
Operating Ambient Temperature TA Range 40 to 125 C
Junction Temperature (max) TJ(max) 165 C