Online Service

Online Service

Contact Person
+86 136 6733 2386
quality Current sensing solution Allegro ACS725LLCTR-50AB-T featuring differential Hall effect and low profile SOIC8 package factory
<
quality Current sensing solution Allegro ACS725LLCTR-50AB-T featuring differential Hall effect and low profile SOIC8 package factory
>
Specifications
working temperature:
-40℃~+150℃
Current Range:
50A
Voltage - Supply:
3V~3.6V
Current Terminal Resistance:
1.2mΩ
Band Width:
120kHz
Response Time (tr):
4us
Sensitivity:
26.4mV/A
Bidirectional Current Detection:
Support
Mfr. Part #:
ACS725LLCTR-50AB-T
Package:
SOIC-8
Key Attributes
Model Number: ACS725LLCTR-50AB-T
Product Description

Product Overview

The Allegro ACS725 is an economical and precise current sensor IC designed for AC or DC current sensing in industrial, automotive, commercial, and communications systems. Its small, low-profile SOIC8 package is ideal for space-constrained applications, reducing board area and costs. The device features differential Hall sensing for common-mode field rejection, a low-resistance primary conductor (1.2 m typical) for minimal power loss and high inrush current capability, and an integrated shield for suppressed output noise. With a high-bandwidth analog output of 120 kHz and patented digital temperature compensation, it offers accurate, fast response times in control applications. The ACS725 provides galvanically isolated current sensing without the need for costly isolation techniques, making it suitable for high-side applications.

Product Attributes

  • Brand: Allegro
  • Package: 8-Pin SOIC (LC)
  • Certifications: AEC-Q100 qualified, CB Certificate Number: US-32848-UL, TV America Certificate Number: U8V 18 02 54214 041, CB 14 11 54214 031
  • Material: Leadframe plated with 100% matte tin; internally Pb-free (except for flip-chip high-temperature Pb-based solder balls)

Technical Specifications

Model Current Sensing Range (IPR) Sensitivity (Typ. mV/A) Operating Temperature (TA) Zero Current Output Voltage (VIOUT(Q)) Total Output Error (ETOT) (Typ. %) Bandwidth (BW) Primary Conductor Resistance (RIP) (Typ.)
ACS725LLCTR-05AB-T 5 A 264 40 to 150 C VCC 0.5 0.9 (25-150C) / 4 (-40-25C) 120 kHz 1.2 m
ACS725LLCTR-10AB-T 10 A 132 40 to 150 C VCC 0.5 0.8 (25-150C) / 4 (-40-25C) 120 kHz 1.2 m
ACS725LLCTR-10AU-T 0 10 A 264 40 to 150 C VCC 0.1 0.9 (25-150C) / 4 (-40-25C) 120 kHz 1.2 m
ACS725LLCTR-20AB-T 20 A 66 40 to 150 C VCC 0.5 0.8 (25-150C) / 4 (-40-25C) 120 kHz 1.2 m
ACS725LLCTR-20AB-T-H 20 A 66 40 to 150 C VCC 0.5 0.7 (25-150C) / 1.5 (-40-25C) 120 kHz 1.2 m
ACS725LLCTR-20AU-T 0 20 A 132 40 to 150 C VCC 0.1 0.8 (25-150C) / 4 (-40-25C) 120 kHz 1.2 m
ACS725LLCTR-30AB-T 30 A 44 40 to 150 C VCC 0.5 0.7 (25-150C) / 4 (-40-25C) 120 kHz 1.2 m
ACS725LLCTR-30AB-T-H 30 A 44 40 to 150 C VCC 0.5 0.7 (25-150C) / 1.5 (-40-25C) 120 kHz 1.2 m
ACS725LLCTR-30AU-T 0 30 A 88 40 to 150 C VCC 0.1 0.8 (25-150C) / 4 (-40-25C) 120 kHz 1.2 m
ACS725LLCTR-40AB-T 40 A 33 40 to 150 C VCC 0.5 1 (25-150C) / 4 (-40-25C) 120 kHz 1.2 m
ACS725LLCTR-50AB-T 50 A 26.4 40 to 150 C VCC 0.5 1 (25-150C) / 4 (-40-25C) 120 kHz 1.2 m
Characteristic Symbol Test Conditions Min. Typ. Max. Unit
Supply Voltage VCC 3 3.3 3.6 V
Supply Current ICC VCC = 3.3 V, output open 10 14 mA
Primary Conductor Resistance RIP TA = 25C 1.2 m
Dielectric Surge Strength Test Voltage VSURGE Tested 5 pulses at 2/minute in compliance to IEC 61000-4-5 1.2 s (rise) / 50 s (width) 6000 V
Dielectric Strength Test Voltage VISO Agency type-tested for 60 seconds per UL standard 60950-1 (edition 2). Production tested at VISO for 1 second, in accordance with UL 60950-1 (edition 2). 2400 VRMS
Working Voltage for Basic Isolation VWVBI Maximum approved working voltage for basic (single) isolation according UL 60950-1 (edition 2) 420 Vpk or VDC / 297 Vrms
Clearance Dcl Minimum distance through air from IP leads to signal leads 4.2 mm
Creepage Dcr Minimum distance along package body from IP leads to signal leads 4.2 mm
Rise Time tr IP = IP(max), TA = 25C, CL = 1 nF 3 s
Propagation Delay tpd IP = IP(max), TA = 25C, CL = 1 nF 2 s
Response Time tRESPONSE IP = IP(max), TA = 25C, CL = 1 nF 4 s
Power-On Time tPO Output reaches 90% of steady-state level, TA = 25C, IP = IPR(max) applied 80 s

Typical Applications

  • Motor control
  • Load detection and management
  • Switched-mode power supplies
  • Overcurrent fault protection

2410010100_ALLEGRO-ACS725LLCTR-50AB-T_C2155515.pdf

Request A Quote

Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible

You Can Upload Up To 5 Files And Each File Sized 10M Max